Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

PHR1445

Supelco

Orlistat

Pharmaceutical Secondary Standard; Certified Reference Material

Sinônimo(s):

Orlistat, (−)-Tetrahydrolipstatin, N-Formyl-L-leucine (1S)-1-[[(2S,3S)-3-hexyl-4-oxo-2-oxetanyl]methyl]dodecyl ester, Ro-18-0647

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula empírica (Notação de Hill):
C29H53NO5
Número CAS:
Peso molecular:
495.73
Número MDL:
Código UNSPSC:
41116107
ID de substância PubChem:
NACRES:
NA.24

grau

certified reference material
pharmaceutical secondary standard

Nível de qualidade

Agency

traceable to USP 1478800

família API

orlistat

Certificado de análise (CofA)

current certificate can be downloaded

embalagem

pkg of 1 g

técnica(s)

HPLC: suitable
gas chromatography (GC): suitable

aplicação(ões)

pharmaceutical (small molecule)

formato

neat

temperatura de armazenamento

2-30°C

cadeia de caracteres SMILES

CCCCCCCCCCC[C@@H](C[C@@H]1OC(=O)[C@H]1CCCCCC)OC(=O)[C@H](CC(C)C)NC=O

InChI

1S/C29H53NO5/c1-5-7-9-11-12-13-14-15-16-18-24(34-29(33)26(30-22-31)20-23(3)4)21-27-25(28(32)35-27)19-17-10-8-6-2/h22-27H,5-21H2,1-4H3,(H,30,31)/t24-,25-,26-,27-/m0/s1

chave InChI

AHLBNYSZXLDEJQ-FWEHEUNISA-N

Informações sobre genes

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.
Orlistat is a specific lipase inhibitor derived from lipostatin, which is naturally produced by Streptomyces toxytricini. Lipase inhibition induced by orlistat reduces the absorption of dietary fat, thereby contributing to caloric deficit.

Aplicação

Orlistat may be used as a pharmaceutical reference standard for the determination of the analyte in plasma samples and pharmaceutical formulations by high performance liquidchromatography techniques.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Ações bioquímicas/fisiológicas

Orlistat, used in obesity research, is a pancreatic lipase inhibitor that acts locally in the gastrointestinal tract to inhibit lipase.

Nota de análise

These secondary standards offer multi-traceability to the USP, EP and BP primary standards, where they are available.

Outras notas

Solution is not completely clear, small particles may remain floating.
This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Nota de rodapé

To see an example of a Certificate of Analysis for this material enter LRAA2822 in the slot below. This is an example certificate only and may not be the lot that you receive.

Produtos recomendados

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Código de classe de armazenamento

11 - Combustible Solids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

A stability-indicating high performance liquid chromatographic assay for the determination of orlistat in capsules
Mohammadi A, et al.
Journal of Chromatography A, 1116(1-2), 153-157 (2006)
Quantitative Determination of Orlistat (Tetrahydrolipostatin, Ro 18-0647) in Human Plasma by High-performance Liquid Chromatography Coupled with Ion Spray Tandem Mass Spectrometry
Bennett PK, et al.
Journal of Mass Spectrometry : Jms, 32(7), 739-749 (1997)
Orlistat, a new lipase inhibitor for the management of obesity
Heck AM
Pharmacotherapy, 20(3), 270-279 (2000)

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica