  • Determination of low levels of benzodiazepines and their metabolites in urine by hollow-fiber liquid-phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS).

Determination of low levels of benzodiazepines and their metabolites in urine by hollow-fiber liquid-phase microextraction (LPME) and gas chromatography-mass spectrometry (GC-MS).

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-12-03)
André Valle de Bairros, Rafael Menck de Almeida, Lorena Pantaleão, Thiago Barcellos, Sidnei Moura e Silva, Mauricio Yonamine
要旨

In this study, it is shown a method for the determination of benzodiazepines and their main metabolites in urine samples by hollow-fiber liquid-phase microextraction (LPME) in the three-phase mode. Initially, the hydrolysis step was performed using 100 μL of sodium acetate 2.0 mol/L buffer solution (pH 4.5), 25 μL of β-glucuronidase enzyme and incubation for 90 min at 55 °C. In parallel with hydrolysis, the LPME fiber (9 cm) was prepared. Its pores were filled with a mixture of dihexyl ether: 1-nonanol (9:1). Afterwards, a solution of 3.0 mol/L of HCl was introduced into the lumen of the fiber (acceptor phase). After hydrolysis, the fiber was submersed in the alkalinized urine (pH 10) containing 10% NaCl. Samples were then submitted to orbital shaking (2400 rpm) for 90 min. The acceptor phase was later withdrawn from the fiber, dried and the residue derivatized with trifluoroacetic anhydride (TFAA) for 10 min at 60 °C with further addition of N-methyl-N-tert-butyldimethylsilyltrifluoroacetamide containing 1% tert-butyldimethylchlorosilane (MTBSTFA) for 45 min at 90 °C followed by determination by gas chromatography-mass spectrometry (GC-MS). The calibration curves obtained showed linearity over the specified range, with a similar sensitivity to traditional techniques and a higher detection capability compared to most of the miniaturized methods described in the literature. The method has been developed and successfully validated and applied to urine samples from real cases of benzodiazepines intake.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
塩酸, ACS reagent, 37%
Sigma-Aldrich
酢酸エチル, ACS reagent, ≥99.5%
Sigma-Aldrich
水酸化ナトリウム, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
酢酸エチル, suitable for HPLC, ≥99.7%
Sigma-Aldrich
塩酸, ACS reagent, 37%
Sigma-Aldrich
水酸化ナトリウム, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
水酸化ナトリウム 溶液, 50% in H2O
Sigma-Aldrich
塩化水素 溶液, 4.0 M in dioxane
Sigma-Aldrich
酢酸エチル, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
酢酸ナトリウム, anhydrous, ReagentPlus®, ≥99.0%
Sigma-Aldrich
水酸化ナトリウム 溶液, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
酢酸ナトリウム, ACS reagent, ≥99.0%
Sigma-Aldrich
塩酸 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
酢酸ナトリウム, puriss. p.a., ACS reagent, reag. Ph. Eur., anhydrous
Sigma-Aldrich
水酸化ナトリウム, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
水酸化ナトリウム 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
塩酸, meets analytical specification of Ph. Eur., BP, NF, fuming, 36.5-38%
Sigma-Aldrich
水酸化ナトリウム, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
塩酸, 37 wt. % in H2O, 99.999% trace metals basis
Sigma-Aldrich
塩化ジルコニル 八水和物, reagent grade, 98%
Sigma-Aldrich
水酸化ナトリウム, reagent grade, 97%, powder
Sigma-Aldrich
塩酸, 36.5-38.0%, BioReagent, for molecular biology
Sigma-Aldrich
塩酸, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., fuming, ≥37%, APHA: ≤10
Sigma-Aldrich
塩化水素 溶液, 2.0 M in diethyl ether
Sigma-Aldrich
水酸化ナトリウム, pellets, semiconductor grade, 99.99% trace metals basis
Sigma-Aldrich
水酸化ナトリウム, puriss. p.a., ACS reagent, reag. Ph. Eur., K ≤0.02%, ≥98%, pellets
Sigma-Aldrich
1-オクタノール, ACS reagent, ≥99%
Sigma-Aldrich
酢酸エチル, suitable for HPLC, ≥99.8%
Supelco
塩酸 溶液, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
tert-ブチルジメチルシリルクロリド, reagent grade, 97%