V-010
(±)-α-Tocopherol-D6 (Vitamin E-D6) solution
500 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Produtos recomendados
grau
certified reference material
Nível de qualidade
Formulário
liquid
embalagem
ampule of 1 mL
fabricante/nome comercial
Cerilliant®
concentração
500 μg/mL in methanol
técnica(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
pf
-97.99 °C
aplicação(ões)
clinical testing
clinical testing
Formato
single component solution
temperatura de armazenamento
−20°C
cadeia de caracteres SMILES
O1[C@@](CCc2c1c(c(c(c2C([2H])([2H])[2H])O)C([2H])([2H])[2H])C)(CCC[C@@H](CCC[C@@H](CCCC(C)C)C)C)C
InChI
1S/C29H50O2/c1-20(2)12-9-13-21(3)14-10-15-22(4)16-11-18-29(8)19-17-26-25(7)27(30)23(5)24(6)28(26)31-29/h20-22,30H,9-19H2,1-8H3/t21-,22-,29-/m1/s1/i5D3,7D3
chave InChI
GVJHHUAWPYXKBD-BCHQTGRQSA-N
Descrição geral
Snap-N-Shoot®
Aplicação
The certified reference material (CRM) in solution can also be used as an internal standard as follows:
- High-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) based combined analysis of retinol, α‐tocopherol, 25‐hydroxyvitamin D2, and 25‐hydroxyvitamin in plasma samples of cardiovascular patients
- Simultaneous determination of 25-hydroxyvitamin-D2 (25-OHD2), 25-hydroxyvitamin-D3 (25-OHD3), and its 3-epimer (epi-25-OHD3), retinol, and α-tocopherol in human serum samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
- Development of two ultra and high-performance liquid chromatographic methods, one coupled with atmospheric pressure chemical ionization and tandem mass spectrometric detector (UHPLC-APCI-MS/MS) and the other one with diode array detector (HPLC-DAD) to estimate fat-soluble vitamins A, D3 and E in rice cereal-based baby food samples
- Multi-residue analysis of fat-soluble vitamins (FSVs)― retinol, 25(OH)D2, 25(OH)D3, epi-25(OH)D3. and α-tocopherol in plasma and amniotic fluid samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS) following a single pre-treatment step
Características e benefícios
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Informações legais
produto relacionado
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Órgãos-alvo
Eyes
Código de classe de armazenamento
3 - Flammable liquids
Classe de risco de água (WGK)
WGK 2
Ponto de fulgor (°F)
49.5 °F - closed cup
Ponto de fulgor (°C)
9.7 °C - closed cup
Escolha uma das versões mais recentes:
Certificados de análise (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.
Se precisar de ajuda, entre em contato Atendimento ao cliente
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Os clientes também visualizaram
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica