RAD405
radiello™ BTEX Calibration Kit (CS2 Desorption)
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Descrição geral
The BTEX Calibration Kit (CS2 Desorption) was designed for the analysis of BTEX in urban environments. The mass of each compound loaded onto each cartridge span the extreme ranges represented in most urban environments. The kit may be used for both routine calibration and quality control. The kit consists of twelve RAD130 Cartridge Adsorbents. Three of which are blanks and nine, divided into three concentration groups, are preloaded with BTEX to simulate 7 day exposures (100,080 minutes). Concentrations are described in the listed table. The values shown are indicative. Actual concentrations are certified for each lot. The cartridges are stable for at least four months when stored at 4°C.
Informações legais
radiello is a trademark of Institi Clinici Scientifici Maugeri
Código de classe de armazenamento
11 - Combustible Solids
Classe de risco de água (WGK)
WGK 1
Ponto de fulgor (°F)
Not applicable
Ponto de fulgor (°C)
Not applicable
Escolha uma das versões mais recentes:
Certificados de análise (COA)
Lamentamos, não temos COA para este produto disponíveis online no momento.
Se precisar de ajuda, entre em contato Atendimento ao cliente
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Os clientes também visualizaram
Passive Sampling of Atmospheric Organic Contaminants
Comprehensive Sampling and Sample Preperation, 1, 201-222 (2012)
Volatile organic compounds in air
Methods for the Determination of Hazardous Substances, 1-17 (1997)
Study of the dispersion of VOCs emitted by a municipal solid waste landfill
Atmospheric Environment, 43 (11), 1926-1931 (2009)
Journal of environmental management, 91(12), 2754-2762 (2010-09-03)
This paper describes a novel methodology for evaluating the extent to which petrol stations affect their surroundings. The method is based on the fact that the ratio of the concentrations of aliphatic and aromatic hydrocarbon pollutants in the air of
High Uptake Rate Radial Diffusive Sampler Suitable for Both Solvent and Thermal Desorption
American Industrial Hygiene Association Journal, 57 (10), 897-904 (1996)
Protocolos
radiello® Diffusive Air Sampling Application - Volatile Organic Compounds (VOCs) Chemically Desorbed With CS2
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica