Pular para o conteúdo
Merck
Todas as fotos(2)

Documentos Principais

A8511

Sigma-Aldrich

Luminol

≥97% (HPLC)

Sinônimo(s):

3-Aminophthalhydrazide, 5-Amino-2,3-dihydro-1,4-phthalazinedione

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula empírica (Notação de Hill):
C8H7N3O2
Número CAS:
Peso molecular:
177.16
Beilstein:
383929
Número CE:
Número MDL:
Código UNSPSC:
12352204
ID de substância PubChem:
NACRES:
NA.83

Nível de qualidade

Ensaio

≥97% (HPLC)

Formulário

powder or chunks

pf

>300 °C (lit.)

solubilidade

DMSO: 50 mg/mL, clear to slightly hazy

cadeia de caracteres SMILES

Nc1cccc2C(=O)NNC(=O)c12

InChI

1S/C8H7N3O2/c9-5-3-1-2-4-6(5)8(13)11-10-7(4)12/h1-3H,9H2,(H,10,12)(H,11,13)

chave InChI

HWYHZTIRURJOHG-UHFFFAOYSA-N

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Luminol is a chemiluminescent compound, which belongs to the class of cyclic acyl hydrazides. It exhibits chemiluminescence, when oxidized by oxidizing agents. Luminol may be associated with nausea, vomiting and mucosa irritation in eyes and skin.

Aplicação

Luminol has been used in chemiluminescence assay.

Características e benefícios

Used for chemiluminescence analysis of, for example, metal cations, blood, and glucococorticoids.

Código de classe de armazenamento

11 - Combustible Solids

Classe de risco de água (WGK)

WGK 3

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable

Equipamento de proteção individual

dust mask type N95 (US), Eyeshields, Gloves


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

Reference values of reactive oxygen species in seminal ejaculates using chemiluminescence assay
Agarwal A, et al.
Journal of Assisted Reproduction and Genetics, 32(12), 1721-1729 (2015)
Luminol-based chemiluminescent signals: clinical and non-clinical application and future uses
Khan P, et al.
Applied Biochemistry and Biotechnology, 173(2), 333-355 (2014)
Christophe A Marquette et al.
Analytical and bioanalytical chemistry, 385(3), 546-554 (2006-05-23)
This critical review discusses the results published between 2000 and 2005 on the development of analytical systems based on the luminol chemiluminescent and electrochemiluminescent reactions. An increasing number of non-specific detection systems based on the enhancing, inhibiting or catalysing effect
Fuan Wang et al.
Chemistry (Weinheim an der Bergstrasse, Germany), 18(50), 16030-16036 (2012-10-20)
The Cu(2+)-dependent ligation DNAzyme is implemented as a biocatalyst for the colorimetric or chemiluminescence detection of Cu(2+) ions, Hg(2+) ions, or cocaine. These sensing platforms are based on the structural tailoring of the sequence of the Cu(2+)-dependent ligation DNAzyme for
Feng-Ming Hsu et al.
Scientific reports, 5, 10291-10291 (2015-05-20)
Esophageal cancer patients with pathological complete response (pCR) to neoadjuvant chemoradiation (CRT) have favorable outcomes. Currently, there was no reliable biomarker predicting the response to CRT. Perioperative circulating mRNA may be associated with prognosis, but its application for predicting treatment

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica