1.59014
Acetonitrile solution
suitable for LC/MS, LiChrosolv®, contains 0.1% (v/v) trifluoroacetic acid
Sinônimo(s):
Acetonitrile solution, ACN, ACN + TFA, Cyanomethane, Ethyl nitrile, Methyl cyanide
About This Item
Produtos recomendados
product name
Acetonitrile with 0.1% (v:v) trifluoroacetic acid, hypergrade for LC-MS LiChrosolv®
pressão de vapor
97 hPa ( 20 °C)
Nível de qualidade
linha de produto
LiChrosolv®
forma
liquid
concentração
0.095-0.105 % (v/v)
técnica(s)
LC/MS: suitable
Impurezas
≤0.025 ppm K (Potassium)
≤0.05 ppm Al (Aluminium)
≤0.05 ppm Ca (Calcium)
≤0.05 ppm Fe (Iron)
≤0.05 ppm Mg (Magnesium)
≤0.25 ppm Na (Sodium)
cor
APHA: ≤10
temperatura de transição
flash point 2 °C
densidade
0.782 g/mL at 25 °C
formato
mixture
temperatura de armazenamento
2-30°C
cadeia de caracteres SMILES
CC#N
InChI
1S/C2H3N/c1-2-3/h1H3
chave InChI
WEVYAHXRMPXWCK-UHFFFAOYSA-N
Procurando produtos similares? Visita Guia de comparação de produtos
Categorias relacionadas
Aplicação
- Retention time prediction for post-translationally modified peptides: Ser, Thr, Tyr-phosphorylation.: This study presents a methodology for predicting retention times of phosphorylated peptides using high-performance liquid chromatography (HPLC) (Battellino et al., 2024).
- Development and validation of a UPLC-PDA method for quantifying ceftazidime in dried blood spots.: This paper outlines a validated ultra-performance liquid chromatography photodiode array (UPLC-PDA) method for the quantification of ceftazidime, demonstrating its application and accuracy in analyzing dried blood samples (Lv et al., 2024).
- A facile fabric phase sorptive extraction method for monitoring chloramphenicol residues in milk samples.: Describes a new method using fabric phase sorptive extraction for the efficient monitoring of chloramphenicol in milk, highlighting its simplicity and effectiveness (Ben Ayed et al., 2024).
- Study of sample preparation influence on bacterial lipids profile in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.: This research investigates how different sample preparation methods affect the lipid profiles of bacteria analyzed by MALDI-TOF MS, providing insights into optimizing protocols for better accuracy (Arendowski et al., 2024).
- Simple and robust LC-MS/MS method for quantification of colistin methanesulfonate and colistin in human plasma for therapeutic drug monitoring.: This article details a robust and straightforward liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of colistin methanesulfonate and colistin in human plasma, useful in clinical settings (Kim et al., 2023).
Nota de preparo
Nota de análise
Identity: passes test
Color: ≤ 10 Hazen
Al (Aluminium): ≤ 0.05 ppm
Ca (Calcium): ≤ 0.05 ppm
Fe (Iron): ≤ 0.05 ppm
K (Potassium): ≤ 0.025 ppm
Mg (Magnesium): ≤ 0.05 ppm
Na (Sodium): ≤ 0.25 ppm
Gradient grade (at 210 nm): ≤ 1.0 mAU
Gradient grade (at 254 nm): ≤ 0.5 mAU
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI positive): ≤ 2 ppb
Filtered by 0.2 µm filter.
Outras notas
Informações legais
produto relacionado
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Código de classe de armazenamento
3 - Flammable liquids
Classe de risco de água (WGK)
WGK 2
Ponto de fulgor (°F)
35.6 °F - (Acetonitrile)
Ponto de fulgor (°C)
2 °C - (Acetonitrile)
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Os clientes também visualizaram
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica