1.00849
Tolueno
for gas chromatography MS Suprasolv®
About This Item
densidade de vapor
3.2 (vs air)
Nível de qualidade
pressão de vapor
22 mmHg ( 20 °C)
26 mmHg ( 25 °C)
linha de produto
SupraSolv®
Ensaio
≥99.8% (GC)
forma
liquid
temperatura de autoignição
997 °F
Lim. expl.
7 %
técnica(s)
GC/MS: suitable
gas chromatography (GC): suitable
Impurezas
≤0.03% Water
resíduo de evaporação
≤3.0 mg/L
cor
APHA: ≤10
índice de refração
n/D 1.496 (lit.)
kinematic viscosity
0.7 cSt(20 °C)
pb
110-111 °C (lit.)
pf
-93 °C (lit.)
temperatura de transição
flash point 4 °C
solubilidade
0.52 g/L
densidade
0.865 g/mL at 25 °C (lit.)
temperatura de armazenamento
2-30°C
cadeia de caracteres SMILES
Cc1ccccc1
InChI
1S/C7H8/c1-7-5-3-2-4-6-7/h2-6H,1H3
chave InChI
YXFVVABEGXRONW-UHFFFAOYSA-N
Procurando produtos similares? Visita Guia de comparação de produtos
Categorias relacionadas
Descrição geral
Aplicação
- Analytical Solution for The Toluene and Mixture of Toluene and n-Propanol in The Biofilm Using ADM.: This study provides an analytical solution for the diffusion and reaction of toluene and its mixtures with n-propanol in biofilms using the Adomian Decomposition Method (ADM). The findings highlight the efficiency of ADM in solving complex diffusion-reaction problems in environmental engineering applications (Valli et al., 2020).
- Benzene, toluene, ethylbenzene, and xylene: Current analytical techniques and approaches for biological monitoring.: This comprehensive review discusses various analytical techniques and biological monitoring approaches for assessing human exposure to toluene and other BTEX compounds. It evaluates the effectiveness of different sample preparation methods and analytical techniques, emphasizing the importance of reliable biomarkers for occupational exposure (Soleimani, 2020).
- Employing UV/peroxydisulphate (PDS) activated by ferrous ion for the removal of toluene in aqueous environment: electrical consumption and kinetic study.: This research investigates the removal of toluene from aqueous environments using UV/peroxydisulphate activated by ferrous ions. The study provides insights into the kinetic parameters and electrical consumption of the process, demonstrating its potential for environmental remediation applications (Shokri, 2020).
- Investigation of some effective factors on urinary metabolites in biological monitoring of benzene, toluene, and xylene compounds.: This paper explores the factors influencing urinary metabolites in the biological monitoring of exposure to benzene, toluene, and xylene (BTX) compounds. It highlights the importance of understanding these factors for accurate assessment of occupational exposure to BTX compounds (Taheri et al., 2022).
Outras notas
Informações legais
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Aquatic Chronic 3 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3
Órgãos-alvo
Central nervous system
Código de classe de armazenamento
3 - Flammable liquids
Classe de risco de água (WGK)
WGK 3
Ponto de fulgor (°F)
39.9 °F
Ponto de fulgor (°C)
4.4 °C
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica