704369
Poly(ethylene glycol) dithiol
average Mn 1, 500, thiol
Sinônimo(s):
Polyethylene glycol, PEG dithiol
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
product name
Poly(ethylene glycol) dithiol, average Mn 1,500
forma
solid
peso molecular
Mn 1200-1800
average Mn 1,500
adequação da reação
reagent type: cross-linking reagent
reactivity: thiol reactive
pf
47-50 °C
Ω-final
thiol
α-final
thiol
arquitetura do polímero
shape: linear
functionality: homobifunctional
temperatura de armazenamento
−20°C
Procurando produtos similares? Visita Guia de comparação de produtos
Aplicação
- Photocurable Bioink for the Inkjet 3D Pharming of Hydrophilic Drugs.: This research discusses the development of a photocurable bioink using poly(ethylene glycol) dithiol for the inkjet 3D printing of hydrophilic drugs. The study highlights the biocompatibility and potential applications in drug delivery systems (Acosta-Vélez et al., 2017).
- Enhanced mechanical properties of photo-clickable thiol-ene PEG hydrogels through repeated photopolymerization of in-swollen macromer.: This study examines the use of poly(ethylene glycol) dithiol in creating thiol-ene hydrogels with enhanced mechanical properties. The repeated photopolymerization technique improves the hydrogel′s stability and applicability in medical devices and tissue engineering (Fiedler et al., 2016).
- Degradative properties and cytocompatibility of a mixed-mode hydrogel containing oligo[poly(ethylene glycol)fumarate] and poly(ethylene glycol)dithiol.: The paper explores the degradative behavior and cytocompatibility of hydrogels composed of oligo[poly(ethylene glycol)fumarate] and poly(ethylene glycol)dithiol. The findings indicate favorable biocompatibility and potential for biomedical applications such as drug delivery and tissue engineering (Brink et al., 2009).
Código de classe de armazenamento
11 - Combustible Solids
Classe de risco de água (WGK)
nwg
Ponto de fulgor (°F)
>230.0 °F
Ponto de fulgor (°C)
> 110 °C
Equipamento de proteção individual
Eyeshields, Gloves, type N95 (US)
Escolha uma das versões mais recentes:
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Os clientes também visualizaram
Biomaterials, 209, 1-9 (2019-04-26)
Segmental injuries to peripheral nerves (PNs) too often result in lifelong disability or pain syndromes due to a lack of restorative treatment options. For injuries beyond a critical size, a bridging device must be inserted to direct regeneration. PN allografts
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica