Przejdź do zawartości
Merck

24136

Supelco

Omegawax Capillary GC Column

L × I.D. 30 m × 0.25 mm, df 0.25 μm

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
41115710
eCl@ss:
32119290

Materiały

fused silica

Poziom jakości

agency

meets requirements for USP G16

Parametry

50-280 °C temperature (isothermal or programmed)

Wartość beta

250

df

0.25 μm

metody

gas chromatography (GC): suitable

dł. × śr. wewn.

30 m × 0.25 mm

grupa aktywna macierzy

Bonded; poly(ethylene glycol) phase

Zastosowanie

agriculture
biofuels
clinical
food and beverages

typ kolumny

capillary polar

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Opis ogólny

Application: This column allows highly reproducible analyses of fatty acid methyl esters (FAMEs), specifically the omega 3 and omega 6 fatty acids. It is tested to ensure reproducible FAME equivalent chain length (ECL) values and resolution of key components.
USP Code: This column meets USP G16 requirements.
Phase:
  • Bonded
  • Poly(ethylene glycol)
Temp. Limits:
  • 50 °C to 280 °C (isothermal or programmed)

Zastosowanie

Capillary GC column with its coated with Omegawax 250 was used for the absorption of analytes from the aqueous sample in-tube solid-phase microextraction coupled with high-performance liquid chromatography. It may also be used in blood lipid fractions by GC-MS analysis.

Inne uwagi

We offer a variety of chromatography accessories including analytical syringes

Informacje prawne

Ta strona może zawierać tekst przetłumaczony maszynowo.

Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Klienci oglądali również te produkty

R O Adlof et al.
Lipids, 35(2), 131-135 (2000-04-11)
This paper deals with the reanalysis of serum lipids from previous studies in which deuterated fatty acids were administered to a single person. Samples were reanalyzed to determine if the deuterated fatty acids were converted to deuterium-labeled conjugated linoleic acid
Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography.
Ralf E and Pawliszyn J.
Analytical Chemistry, 69 (16), 3140-3147 (1997)
Susana P Alves et al.
Journal of chromatography. A, 1216(26), 5130-5139 (2009-05-19)
Two gas-liquid chromatograph capillary columns for the analysis of fatty acids (FA) in ruminant fat are compared. Those columns are the CP-Sil 88 of 100 m long with a highly polar stationary phase and the Omegawax 250 of 30 m
M Vecka et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 770(1-2), 91-99 (2002-05-16)
Four capillary columns (A: CP-WAX 52 CB 25 m x 0.25 mm; B: CP WAX 52 CB 30 m x 0.25 mm; C: CP-WAX 58 CB 25 m x 0.25 mm, Chrompack; D: OMEGAWAX 320 30 m x 0.32 mm
H Kataoka et al.
Analytical chemistry, 71(19), 4237-4244 (1999-10-12)
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) was evaluated for the determination of beta-blockers in urine and serum samples. In-tube SPME is an extraction technique for organic compounds in aqueous samples

Produkty

This technical article will discuss GC Analysis of a 37-Component FAME Mix on Omegawax.

Compared to existing ‘wax’ columns, the SLB-IL60 column offers unique selectivity, some cis/trans resolution, and faster elution for the analysis of omega 3 and omega 6 fatty acid methyl esters.

Protokoły

Determination of the fatty acid composition of nuts using established methods for GC analysis on capillary columns of 3 selectivities: Omegawax, SP-2560, and ionic liquid based SLB-IL111.

nalysis of the omega 3 fatty acid profiles from fish oil capsules and salmon, highlighted through the use of 2 GC columns of different selectivity for analysts who wish to perform confirmatory analysis.

-Cymene; 2,5-Dimethylpyrrole; Acetoin, ≥96%, FCC, FG; 2,5-Dimethylpyrazine; 2,6-Dimethylpyrazine; 2-Ethylpyrazine, ≥98%, FG; 2,3-Dimethylpyrazine; 4-Heptanone; 3-Ethylpyridine; 2,3,5-Trimethylpyrazine; Furfural; Pyrrole; Furfuryl acetate; Linalool; Linalyl acetate; 5-Methylfurfural; γ-Butyrolactone; 2-Acetyl-1-methylpyrrole; Furfuryl alcohol; 2-Acetylpyrrole; Pyrrole-2-carboxaldehyde

Chromatograms

application for SPME, suitable for GCsuitable for GCsuitable for GCsuitable for GCPokaż więcej

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej