GE28-9924-73
HiScreen™ Capto™ Butyl
Cytiva 28-9924-73, pack of 1 column
Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych
About This Item
Polecane produkty
ligand
butyl
opakowanie
pack of 1 column
producent / nazwa handlowa
Cytiva 28-9924-73
wymiary złoża
7.7 mm × 100 mm
kolumna śr. wewn.
7.7 mm
Matryca
highly cross-linked agarose
śr. rozm. cząst.
75 μm (d50v)
cleaning
3-14
Zakres roboczy
3-13
pojemność
27 mg binding capacity(27 mg BSA /ml (at QB10%))
przydatność
suitable for bioprocess medium
Opis ogólny
Capto™ Phenyl (High sub) and Capto™ Butyl are hydrophobic interaction chromatography (HIC) media used in the capture and intermediate stages of protein purification.
Zastosowanie
HiScreen™ columns are part of the process development platform available from Cytiva. The columns are prepacked with a range of BioProcess chromatography media (resins) and designed for method optimization and parameter screening. HiScreen™ columns have small bed volumes (4.7 ml), reducing the cost of sample and buffer consumption. The media used in HiScreen™ columns are also available in other prepacked formats and as bulk packs, for all scales of work from development and pilot studies to routine production.
Capto™ Butyl is intended for initial and intermediate step purifications requiring a chromatography medium with Low to medium hydrophobicity. Capto™ Butyl often works efficiently with rather Low salt concentrations. The mechanism of binding and elution onto the butyl ligand is different from that onto the phenyl ligand, giving a different selectivity. Performance during sample run and selectivity are similar to that of Butyl Sepharose™ 4 Fast Flow. Higher flow rates can be used with Capto™ Butyl during equilibration, wash and regeneration.
Capto™ Butyl is intended for initial and intermediate step purifications requiring a chromatography medium with Low to medium hydrophobicity. Capto™ Butyl often works efficiently with rather Low salt concentrations. The mechanism of binding and elution onto the butyl ligand is different from that onto the phenyl ligand, giving a different selectivity. Performance during sample run and selectivity are similar to that of Butyl Sepharose™ 4 Fast Flow. Higher flow rates can be used with Capto™ Butyl during equilibration, wash and regeneration.
Cechy i korzyści
- Prepacked with Capto™ Butyl
- Excellent for method optimization and parameter screening due to the 10 cm bed height
- Easily connected in series to achieve 20 cm bed height
- Small bed volume for fast results and minimal sample/buffer consumption
- Reproducible results, scalable to BioProcess columns packed with the same media using the same flow velocity
Przechowywanie i stabilność
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol)
Komentarz do analizy
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
Informacje prawne
Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva
Sepharose is a trademark of Cytiva
Ta strona może zawierać tekst przetłumaczony maszynowo.
produkt powiązany
Hasło ostrzegawcze
Warning
Zwroty wskazujące rodzaj zagrożenia
Zwroty wskazujące środki ostrożności
Kod klasy składowania
3 - Flammable liquids
Wybierz jedną z najnowszych wersji:
Certyfikaty analizy (CoA)
Przepraszamy, ale COA dla tego produktu nie jest aktualnie dostępny online.
Proszę o kontakt, jeśli potrzebna jest pomoc Obsługa Klienta
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej