MVP ICON® Surface Sampling Device
BioControl, ATP Surface Sampling Swab for HACCP Management
Synonim(y):
ATP swab tip
Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych
About This Item
Polecane produkty
Poziom jakości
linia produktu
FLASH®
opakowanie
pkg of 100 units (swabs; BC64003-100TST)
producent / nazwa handlowa
MVP ICON®
warunki przechowywania
room temperature
Zastosowanie
food and beverages
personnel monitoring (monitoring)
surface monitoring
kompatybilność
for use with MVP ICON instrument
metoda wykrywania
bioluminescent
temp. przechowywania
2-30°C
room temp
Opis ogólny
The MVP ICON® Surface Sampling Device is a self-contained device for use with the MVP ICON® system for quality and HACCP-related monitoring of the environment. The sampling device does not puncture seals during activation, but lets the reagent flow down the swab shaft, and uniformly releases ATP sample from the tip. The MVP ICON® Surface Sampling Device is designed to compensate for variations in swabbing technique, thus offering accurate and consistent readings every time.
The MVP ICON® system detects food and microbiological residues by measuring Adenosine triphosphate (ATP) using luciferase bioluminescence. ATP is found in most food residues and all bacteria, yeast, and mold cells.
The MVP ICON® system detects food and microbiological residues by measuring Adenosine triphosphate (ATP) using luciferase bioluminescence. ATP is found in most food residues and all bacteria, yeast, and mold cells.
Zastosowanie
MVP ICON® Surface Sampling Device is used with the MVP ICON® system to detect food and microbiological residues during hygiene monitoring for the Food and Beverage industries.
Cechy i korzyści
Increase Confidence in Your Results
Create More Flexibility in Your Schedule
Convenient Storage
- Superior swab design eliminates variation in operator′s collection technique, increasing reproducibility and providing assurance swab will be accurately and consistently measured each time.
- Light output of the reagent is measured, not the solid device surface, ensuring a high degree of repeatability.
- Reagent flows through hollow sampling device shaft to evenly wash ATP off sampling tip into bottom of the collection tube, ensuring a high degree of accuracy.
- Sampling devices feature one-hand, one-step activation freeing one hand for other operations.
Create More Flexibility in Your Schedule
- The swab′s proprietary neutralizing buffer minimizes potential sanitizer interference so measurements can be taken before OR after sanitizing, letting you decide when it is most convenient to conduct your testing.
- Minimizes potential effect of commonly used sanitizers such as: Quat, Chlorine, and Peracetic Acid.
- Reduces false negative and false positive results caused by the quenching or amplification of sanitizers on competing swabs.
Convenient Storage
- Store sampling devices at room temperature – no refrigeration needed; saving precious refrigeration space for other necessities.
Komponenty
All test reagents are contained within the sampling device.
Przydatność
ATP Testing, Food Processing, HACCP Monitoring, Sanitation
Zasada
The detection of ATP through bioluminescence is a well-established and widely used indicator of surface hygiene and cleaning efficacy in food processing. Visual inspection is not an adequate critical control for surface hygiene and the lengthy time-to-result of microbiological test methods (from 2 - 7 days) make them ineffective for hygiene monitoring. ATP detection with the MVP ICON provides results in 10 seconds allowing for immediate "go/no-go" decisions to be made prior to the start of processing and allows for correction actions, when necessary, to be taken immediately. ATP is a molecule that is found in all living cells, including: bacteria, yeast, mold and all organic matter. After cleaning and/or sanitizing, food processing equipment and the plant environment is tested for ATP. If cleaning/sanitizing has been effective, ATP levels should be low.
Metoda testowania
ATP Bioluminescence
Przechowywanie i stabilność
Store at 2 to 30 °C (Protect from direct sunlight. Unused devices must be resealed in the foil bags.)
Informacje prawne
FLASH is a registered trademark of Merck KGaA, Darmstadt, Germany
MVP ICON is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.
Hasło ostrzegawcze
Warning
Zwroty wskazujące rodzaj zagrożenia
Zwroty wskazujące środki ostrożności
Klasyfikacja zagrożeń
Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1
Kod klasy składowania
12 - Non Combustible Liquids
Wybierz jedną z najnowszych wersji:
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Klienci oglądali również te produkty
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej