MVP ICON® ATP Calibrator Set

MVP ICON®, ATP Luminometer Calibration

Synonim(y):

ATP Calibrator Set, ATP Measurement Calibration Kit, Quality Control ATP Calibrator

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
41122409
NACRES:
NB.79

agency

EP
ISO
USP

linia produktu

MVP ICON®

okres trwałości

5 yr

Właściwości

ready-to-use

producent / nazwa handlowa

MVP ICON®

opakowanie

set of calibrator rods

warunki przechowywania

protect from light (Keep in a tightlyclosed container, away from any light sources)

Zastosowanie

food and beverages

kompatybilność

for use with MVP ICON instrument

temp. przechowywania

15-25°C

Opis ogólny

MVP ICON® ATP Calibrator Set consists of two calibration devices (“rods”) that are used for performance verification and calibration of the MVP ICON® and MVP systems. The luminescent calibrator consists of a 14C radioactive source that emits a very low level (5 x 105 d.p.m., or 0.225 microcuries) of low-energy ß-radiation in a plastic scintillation matrix. This matrix is configured to give constant light output, within 10 % of its original value, at a sufficiently high level to make consistent verification and calibration functions possible over the five‐year life of the calibrator. The non‐luminescent black plastic calibrator provides a reliable low‐end or “dark” source reading.

Zastosowanie

MVP ICON® ATP Calibrator Set is used for performance verification and calibration of the MVP ICON® instrument for rapid monitoring of surface hygiene in the Food and Beverage industries.

Cechy i korzyści

  • On-site calibration
  • Satisfies HACCP and GMP requirements
  • No need to send the equipment out to a 3rd party.

Komponenty

  • One luminescent calibrator
  • One non-luminescent calibrator

Przydatność

ATP Testing, Food Processing, HACCP Monitoring, Sanitation

Zasada

The luminescent calibrator consists of a 14C radioactive source that emits a very low level (5 x 105 d.p.m., or 0.225 microcuries) of low energy ß radiation in a plastic scintillation matrix. This matrix is configured to give constant light output, within 10% of its original value, at a sufficiently high level to make consistent verification and calibration functions possible over the five- year life of the calibrator. The non-luminescent black plastic calibrator provides a reliable low-end or “dark” source reading.

Metoda testowania

ATP Bioluminescence

Przechowywanie i stabilność

To ensure the stability and longevity of the luminescent calibrator, the following precautions must be taken:
  • Limit Exposure to Light.
  • Store the luminescent calibrator in the dark or weak ambient light.
  • If the luminescent calibrator is exposed to bright light before use, insert it in the MVP ICON® or MVP and wait a minimum of 2 minutes before proceeding.
  • The kit box provided is recommended as an appropriate dark storage.
  • Do not expose to direct sunlight or intense artificial light before use.

Inne uwagi

Avoid crushing, cutting, or dropping the calibrators.

Informacje prawne

BioControl is a registered trademark of BioControl Systems, Inc.
MVP ICON is a registered trademark of Merck KGaA, Darmstadt, Germany
This page may contain text that has been machine translated.

Elementy zestawu są też dostępne oddzielnie

Numer produktu
Opis
Karta charakterystyki

  • 72001SBCLuminescent Calibrator RodKarta charakterystyki

  • Non Luminescent Calibrator Rod

Kod klasy składowania

10 - Combustible liquids

Temperatura zapłonu (°F)

Not applicable

Temperatura zapłonu (°C)

Not applicable


Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Klienci oglądali również te produkty

Slide 1 of 1

1 of 1

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej