P3C003C10
Pellicon® 3 Cassette with Ultracel® Membrane
filtration area 1.14 m2, NMWCO 3 kDa
Synonim(y):
Pellicon® 3 Cassette with Ultracel 3 kDa Membrane, C screen, 1.14 m2
About This Item
Polecane produkty
Materiały
TPE seal
composite regenerated cellulose (CRC)
polypropylene screen
stainless steel cap (for end; polypropylene-encapsulated)
Poziom jakości
Właściwości
holdup volume 170 mL (in feed channel)
producent / nazwa handlowa
Pellicon®
Parametry
30 psi max. reverse press. exposure at 25 °C (for 24 hours)
4-6 L/min-m2 recirculation rate
40 psi max. transmembrane pressure at 4-50 °C
6.9 bar max. inlet pressure (100 psi)
80 psi max. transmembrane pressure at 4-40 °C
metody
analytical sample preparation: suitable
buffer exchange: suitable
protein purification: suitable (concentration)
Wysokość
3.8 cm (1.51 in.)
Długość
20.6 cm (8.1 in.)
Szerokość
17.8 cm (7 in.)
powierzchnia filtracyjna
1.14 m2
powierzchnia membrany
1.14 m2
substancje ekstrahujące się grawimetrycznie
≤1500 mg/m2
macierz
Ultracel® (Membrane)
wielkość porów
3 kDa NMWCO
pH
2-13
Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów
Powiązane kategorie
Opis ogólny
The Pellicon® 3 Cassette with Ultracel® Membrane is designed for the filtration of therapeutic proteins (such as monoclonal antibodies) and recombinant and non-recombinant proteins.
This P3C003C10 Pellicon® 3 ultrafiltration device features a pore size of 3 kDa NMWCO, a filtration area of 1.14 m2, a PLCCC membrane, and dimensions measuring 2.4 cm (H) x 17.8 cm (W) x 20.6 cm (L).
Cechy i korzyści
- Rugged & reliable – ideally suited for today′s more demanding filtration processes
- High performance – produces excellent resolution, yields and back-pressure resistance
- Optimum product recovery – thanks to proven membrane technology
- Void-free technology – leading-edge membranes resolve virtually any separation challenge
- Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
- Automated manufacturing – delivers unbeatable performance, consistency and reliability
- Easy installation & care – simple to install and maintain
Inne uwagi
Komentarz do analizy
Informacje prawne
Kod klasy składowania
8A - Combustible, corrosive hazardous materials
Klasa zagrożenia wodnego (WGK)
WGK 1
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej