Key Documents

G005848

LC/MS/MS Analysis of DL-d-Hydroxyglutaric Acid Enantiomers on Astec® CHIROBIOTIC® R

application for HPLC

ログイン組織・契約価格を表示する


About This Item

テクニック

HPLC: suitable

試験パラメータ

column: CHIROBIOTIC R, 25 cm x 4.6 mm I.D., 5 μm particles (13024AST)
mobile phase: (A) ethanol:methanol (3:1, v:v); (B) 0.1% v/v TEA in water, adjusted to pH 4.5 with acetic acid; 75:25 (A:B)
flow rate: 0.4 mL/min
column temp.: 20 °C
detector: MS, ESI(-), 100-1000 m/z
injection: 5 μL
sample: each enantiomer, 100 μg/mL in water

適合性

application for HPLC

アプリケーション

clinical
forensics and toxicology
life science and biopharma

アナリシスノート

Chiral 2-hydroxyglutarates (2-OHG) are important molecular signatures of both healthy and diseased biological cells, their specific biochemical pathways and inborn errors of metabolism. The chiral differentiation and quantification of D-2-OHG (R(-)-2-OHG) and L-2-OHG (S(+)-2-OHG) is key for characterizing neurometabolic disorders like the 2-hydroxyglutaric acidurias that cause neurological impairment early in life. The ability to distinguish and quantify the enantiomers of 2-OHG is therefore important to be able to track its disposition throughout the metabolic pathway of normal vs. mutated cells. We show here a rapid and sensitive method to separate and measure D-2-OHG and L-2-OHG using LC-MS/MS detection. An Astec® CHIROBIOTIC R (ristocetin chiral selector) column was run under polar ionic mobile phase conditions. Using tandem MS eliminated two fundamental analytical challenges with these compounds: the lack of a UV-absorbing chromophore in the 2-OHG molecule, and the abundance of competing low molecular weight acids in urine. The upper panel in the chromatogram shows the separation of D-2-OHG and L-2-OHG obtained during method development. The lower panel shows the pure L-2-hydroxyglutaric acid.
Besides providing the necessary enantioselectivity, Astec® CHIROBIOTIC columns have the advantage of operating in aqueous and polar organic mobile phases that are amenable to polar drugs and metabolites. Their ionic interactions promote analyte ionization which enhances sensitivity in ESI detection. In addition to the CHIROBIOTIC columns, Sigma-Aldrich also provides the high purity mobile phase agents, racemic and pure chiral 2-OHG enantiomers and other compounds in the isocitrate dehydrogenase (IDH) pathway.

法的情報

Astec is a registered trademark of Merck KGaA, Darmstadt, Germany
CHIROBIOTIC is a registered trademark of Sigma-Aldrich Co. LLC

アナライト

詳細

    L-α-Hydroxyglutaric acid disodium salt, ≥98.0% (GC)
    D-α-Hydroxyglutaric acid disodium salt, ≥95% (GC)

最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

申し訳ございませんが、現在この製品のCOAをオンラインで入手できません。

サポートが必要な場合は、お問い合わせください カスタマーサポート

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)