コンテンツへスキップ
Merck

CGEP71TP1

Millipore

ミリポアエクスプレス(Millipore Express)® SHF、カートリッジ

pore size 0.2 μm, cartridge nominal length 10 in. (25 cm), Code 7, silicone seal

別名:

Millipore Express SHF Cartridge Filter 10 in. 0.2 μm Code 7 Silicone

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
23151806
eCl@ss:
32031690

物質

polyethersulfone
polypropylene
polypropylene support
polysulfone
silicone seal

品質水準

法規制遵守

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

無菌性

non-sterile

滅菌適合性

autoclavable compatible
steam-in-place compatible

製品種目

EMPROVE® Filter
Millipore Express®

特徴

hydrophilic

メーカー/製品名

Millipore Express®

パラメーター

≤30 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
0.07 bar max. inlet pressure (1 psi) at 135 °C (Reverse)
0.35 bar max. inlet pressure (5 psi) at 135 °C (Forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (Forward)
1700 bar max. differential pressure (25 psi) at 80 °C (Forward)
2.07 bar max. inlet pressure (30 psi) at 25 °C (Reverse)
2100 mbar max. differential pressure (30 psi) at 25 °C (Reverse)
340 mbar max. differential pressure (5 psi) at 135 °C (Forward)
69 mbar max. differential pressure (1 psi) at 135 °C (Reverse)
6900 mbar max. differential pressure (100 psi) at 25 °C (Forward)
7 bar max. inlet pressure (100 psi) at 25 °C (Forward)

テクニック

sterile filtration: suitable

L

10 in.

W

2.7 in.

カートリッジの長さ(公称)

10 in. (25 cm)

直径

6.9 cm (2.7 in.)

ろ過面積

0.54 m2

不純物

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

マトリックス

Millipore Express® SHF

ポアサイズ

0.2 μm pore size

入力

sample type liquid

泡立ち点

≥4000 mbar (58 psig), air with water at 23 °C

カートリッジコード

Code 7

類似した製品をお探しですか? 訪問 製品比較ガイド

関連するカテゴリー

詳細

Device Configuration: カートリッジ

包装

ダブル イージーオープン バッグ

その他情報

これらの製品はFDAの定めたGMP準拠の製造工場で製造されています。
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
  • Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

調製ノート

Sterilization Method
135 °C 30 分のSIP 25回または正方向22回および逆方向3回; 2126 °C 60 分のオートクレーブ滅菌 5回
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

アナリシスノート

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
次の水でフラッシング後USP Oxidizable Substances Testに適合 ≥1 L
TOC/Conductivity
After sterilization and a controlled water flush of 10 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.

法的情報

ASTM is a registered trademark of American Society for Testing and Materials
Emprove is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany

Not finding the right product?  

Try our 製品選択ツール.


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)