Pular para o conteúdo
Merck

Drag-reducing polymers: a novel class of diuretic and natriuretic compounds.

Cardiovascular drugs and therapy (1990-02-01)
D D Smyth, P I Polimeni
RESUMO

Previous studies have demonstrated that Separan AP-30, a drag-reducing polymer, significantly decreased the formation of atherosclerotic plaques in rabbits fed a high-cholesterol diet. Furthermore, Separan AP-273, a polymer similar to but longer than Separan AP-30, markedly increased cardiac output in open-chest rats. Preliminary studies in our laboratory have described diuresis and natriuresis following the intravenous infusion of Separan AP-273. These studies did not determine whether this natriuresis was common to drag-reducing polymers or unique to Separan. In the present study the renal effects of two chemically dissimilar drag-reducing polymers of molecular lengths approaching approximately 100 microns were compared. Sprague-Dawley rats (250-300 g) were anesthetized (Nembutal) and a tracheostomy was performed. A baseline level of sodium and water excretion was established by the infusion of saline (0.097 ml/min, IV). Separan (0.004%), an anionic polyacrylamide; Polyox (0.4%), a poly(ethylene oxide); or mannitol (20%), an osmotic diuretic, was infused into the jugular vein at 0.0034 ml/min. Separan and Polyox both increased the excretion of sodium and water (p less than 0.05). At the doses tested, potassium excretion was unaltered in both groups. Separan, but not Polyox, produced a modest increase in blood pressure. Creatinine clearance was unaltered. At this infusion rate, only hypertonic concentrations of mannitol (20%) induced a similar effect. These results indicate that drag-reducing polymers may represent a novel class of potassium-sparing diuretic and natriuretic compounds. The ability of this class of polymers to decrease the formation of atherosclerotic plaques, increase blood flow, and produce a potassium-sparing natriuresis may be of practical clinical significance.

MATERIAIS
Número do produto
Marca
Descrição do produto

Sigma-Aldrich
Poli(etilenoglicol), average Mn 400
Sigma-Aldrich
Poli(etilenoglicol), BioUltra, 8,000
Sigma-Aldrich
Poli(etilenoglicol), average mol wt 8,000, powder
Sigma-Aldrich
Poli(etilenoglicol), average Mn 6,000
Sigma-Aldrich
Poly(ethylene oxide), average Mv 100,000 (nominal), powder
Sigma-Aldrich
Poli(etilenoglicol), average Mn 3,350, powder
Sigma-Aldrich
Poli(etilenoglicol), average Mn 300
Sigma-Aldrich
Poli(etilenoglicol), average Mn 20,000
Sigma-Aldrich
Poly(ethylene oxide), average Mv 600,000 (nominal), powder
Sigma-Aldrich
Poli(etilenoglicol), BioUltra, 4,000
Sigma-Aldrich
Poli(etilenoglicol), average Mn 4,000, platelets
Sigma-Aldrich
Poli(etilenoglicol), average mol wt 200
Sigma-Aldrich
Poli(etilenoglicol), average mol wt 400
Sigma-Aldrich
Poli(etilenoglicol), 35,000
Sigma-Aldrich
Polyethylene glycol solution, Hybri-Max, 50 % (w/v), average mol wt 1,450, 0.2 μm filtered, BioReagent, suitable for hybridoma
Sigma-Aldrich
Poli(etilenoglicol), BioUltra, 35,000