1.50443
SeQuant™ ZIC®-HILIC 100Å (3.5 µm) HPLC Columns
L × I.D. 250 mm x 2.1 mm HPLC Column, PEEK-lined stainless steel
About This Item
Produtos recomendados
product name
SeQuant™ ZIC-HILIC™ 3.5µm,100Å 250 x 2.1 mm, PEEK-lined stainless steel column, suitable for HPLC
Materiais
PEEK-lined stainless steel column
Nível de qualidade
Agency
suitable for USP L114
linha de produto
SeQuant™
Características
endcapped: no
Parâmetros
550 bar pressure
70 °C max. temp.
técnica(s)
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)
coluna C × D.I.
25 cm × 2.1 mm
matriz
fully porous particle
Grupo ativo da matriz
ZIC-HILIC bonding phase
tamanho de partícula
3.5 μm
tamanho de poro
100 Å pore size
pH operacional
2-7.5
técnica de separação
hydrophilic interaction (HILIC)
temperatura de armazenamento
no temp limit
Descrição geral
The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.
The Pore size of 100 Å makes this column perfectly suitable for the separation of small polar molecules under HILIC conditions.
The column dimension of 250 mm length x 2.1 mm ID is the optimal choice for the separation of complex samples using a UHPLC or optimized HPLC Instrument providing low dwell volumes.
Thanks to their favorable retention and robust performance, SeQuant™ HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant™ ZIC®-HILIC for analysis of melamine and related substances.
SeQuant™ HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.
Learn more about the Supelco HPLC Column portfolio and Method development:
Brochure: HPLC and UHPLC Column Selection Guide
Brochure: A Practical Guide to HPLC - Method Development Guide
Nota de análise
Symmetry (Cytosine): 0.95 - 1.40
Informações legais
produto relacionado
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica