1.50436

Supelco

SeQuant® ZIC®-HILIC 200Å (5 µm) HPLC Columns

L × I.D. 20 mm x 2.1 mm, Guard Kit with holder and Guard Column

Sinônimo(s):

Hydrophilic Interaction Liquid Chromatography Guard Column

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41115709

Nome do produto

SeQuant® ZIC-HILIC Guard Kit 20 x 2.1 mm, PEEK-lined stainless steel column, pkg of 3 column

Materiais

PEEK-lined stainless steel column

Nível de qualidade

Agency

suitable for USP L114

linha de produto

SeQuant®

Características

endcapped: no

embalagem

pkg of 3 column

Parâmetros

550 bar pressure
70 °C max. temp.

técnica(s)

LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)

coluna C × D.I.

2 cm × 2.1 mm

Matriz

fully porous particle

Grupo ativo da matriz

ZIC-HILIC bonding phase

tamanho de partícula

5 μm

tamanho de poro

200 Å pore size

pH operacional

2-7.5

técnica de separação

hydrophilic interaction (HILIC)

temperatura de armazenamento

no temp limit

Descrição geral

The SeQuant® ZIC®-HILIC Guard column protects your analytical column from contamination. The guard column kit contains 3 Guard columns including the coupler.
SeQuant® ZIC®-HILIC Columns are designed to retain and separate all types of polar and hydrophilic compounds and for robust chromatography with high selectivity and reproducibility.
The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.
Thanks to their favorable retention and robust performance, SeQuant® HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant® ZIC®-HILIC for analysis of melamine and related substances.
SeQuant® HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.
Learn more about the Supelco HPLC Column portfolio and Method development:
Brochure: HPLC and UHPLC Column Selection Guide
Brochure: A Practical Guide to HPLC - Method Development Guide

Informações legais

SeQuant is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC-HILIC is a trademark of Merck KGaA, Darmstadt, Germany

Código de classe de armazenamento

11 - Combustible Solids


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

Slide 1 of 1

1 of 1

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica