Skip to Content
MilliporeSigma
  • Simultaneous determination of 14-thienyl methylene matrine and matrine in rat plasma by high-performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study.

Simultaneous determination of 14-thienyl methylene matrine and matrine in rat plasma by high-performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-12-03)
Minjie Jiang, Lisheng Wang, Weizhe Jiang, Shulin Huang
ABSTRACT

A rapid, sensitive and selective high-performance liquid chromatography-tandem mass spectrometric method (HPLC-MS) has been developed and validated for the simultaneous determination of 14-thienyl methylene matrine (TMM) and matrine (MT) in rat plasma in the present study. The analytes were separated on a C18 column (1.9 μm, 2.1 mm × 100 mm) with a security guard C18 column (5 μm, 2.1 mm × 10 mm) and a triple-quadrupole mass spectrometry equipped with an electrospray ionization (ESI) source was applied for detection. With pseudoephedrine hydrochloride as internal standard, sample pretreatment involved in a one-step protein precipitation with isopropanol:ethyl acetate (v/v, 20:80). The method was linear over the concentration ranges of 5-1000 ng/ml for TMM and 10-2000 ng/ml for MT. The intra-day and inter-day relative standard deviations (RSD) were less than 15% and the relative errors (RE) were all within 15%. The proposed method enables unambiguous identification and quantification of TMM and MT in vivo. This was the first report on determination of the TMM and MT in rat plasma after oral administration of TMM. The results provided a meaningful basis for evaluating the clinical applications of the medicine.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Supelco
Acetonitrile, HPLC grade, ≥99.93%
Supelco
2-Propanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
(+)-Pseudoephedrine hydrochloride, ≥98%
Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Supelco
2-Propanol, analytical standard
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
2-Propanol, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
2-Propanol, suitable for HPLC, 99.5%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
2-Propanol, suitable for HPLC, 99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
2-Propanol, ACS reagent, ≥99.5%
Sigma-Aldrich
2-Propanol, puriss., meets analytical specification of Ph. Eur., BP, USP, ≥99.5% (GC)
Sigma-Aldrich
2-Propanol, puriss. p.a., ACS reagent, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
2-Propanol, for molecular biology, BioReagent, ≥99.5%
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
2-Propanol, ACS reagent, ≥99.5%
Sigma-Aldrich
2-Propanol, 99.5%, HPLC grade
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
2-Propanol, JIS special grade, ≥99.5%