MilliporeSigma
All Photos(1)

C-28075

Sigma-Aldrich

3D Tumorsphere Medium XF

Ready-to-use kit including Basal Medium and SupplementMix, phenol red-free, 250 ml

form

liquid

packaging

pkg of 250 ml

technique(s)

cell culture | mammalian: suitable

shipped in

wet ice

Compare Similar Items

View Full Comparison

1 of 4

This Item
C-28070C-28077C-28019
form

liquid

form

liquid

form

liquid

form

liquid

packaging

pkg of 250 ml

packaging

pkg of 250 ml

packaging

pkg of 250 ml

packaging

pkg of 500 ml

technique(s)

cell culture | mammalian: suitable

technique(s)

cell culture | mammalian: suitable

technique(s)

cell culture | mammalian: suitable

technique(s)

cell culture | mammalian: suitable

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

General description

3D Tumosphere Medium XF, phenol red-free

Application

The 3D Tumorsphere Medium XF is a culture system developed for the standardized serial culture of cancer cell lines as tumorspheres/mammospheres. The formulation supports sustained cell proliferation allowing for serial passage of the 3D culture. Its serum-free and xeno-free formulation provides a culture environment devoid of all stimuli originating from non-defined materials.3D Tumorsphere Medium XF consists of a bottle of phenol red-free Basal Medium and one vial of SupplementMix. Adding the SupplementMix to the Basal Medium results in the complete medium.

Quality

All lots of the PromoCell 3D Tumorsphere Medium XF are subjected to comprehensive quality control tests using human mammary cancer cells. Each lot of PromoCell 3D Tumorsphere Medium XF is tested for the ability to support tumorsphere/mammosphere formation, proliferation and serial passage of the 3D culture. In addition, all lots of media have been tested for the absence of microbial contaminants (fungi, bacteria, mycoplasma).

Preparation Note

3D Tumorsphere Medium XF contains all growth factors and supplements. The medium does not contain antibiotics or antimycotics and is formulated for use in an incubator with an atmosphere of 5% CO2.Thaw the SupplementMix at 15 to 25°C. Aseptically mix the supplement solution by carefully pipetting up and down. Then, transfer the entire content of the SupplementMix to the Basal Medium. Close the bottle and swirl gently until a homogenous mixture is formed.

Storage and Stability

Store the Basal Medium at 4 to 8°C in the dark, store the SupplementMix at -20°C immediately after arrival. Do not freeze the Basal Medium. If stored properly, the products are stable until the expiry date stated on the label. After adding the SupplementMix to the Basal Medium, the shelf life of the complete medium is 6 weeks at 4 to 8°C. For use, pre-warm only an aliquot of the complete medium and keep the remaining medium refrigerated at 4 to 8°C.

Subculture Routine

Click here for more information.

Storage Class Code

10 - Combustible liquids

WGK

WGK 2


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service