MilliporeSigma
All Photos(1)

52750

Supelco

Hexane

analytical standard

Synonym(s):
n-Hexane
Linear Formula:
CH3(CH2)4CH3
CAS Number:
Molecular Weight:
86.18
Beilstein:
1730733
EC Number:
MDL number:
PubChem Substance ID:
NACRES:
NA.24

Quality Level

grade

analytical standard

vapor density

~3 (vs air)

vapor pressure

256 mmHg ( 37.7 °C)
5.2 psi ( 37.7 °C)
~132 mmHg ( 20 °C)

assay

≥99.7% (GC)

autoignition temp.

453 °F

shelf life

limited shelf life, expiry date on the label

expl. lim.

7.7 %

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

refractive index

n20/D 1.375 (lit.)
n20/D 1.375

bp

69 °C (lit.)

mp

−95 °C (lit.)

density

0.659 g/mL at 25 °C (lit.)

application(s)

cleaning products
cosmetics
food and beverages
personal care
petroleum

format

neat

SMILES string

CCCCCC

InChI

1S/C6H14/c1-3-5-6-4-2/h3-6H2,1-2H3

InChI key

VLKZOEOYAKHREP-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
Hexane has been used as a solvent in the detection of rubrene using normal phase high performance liquid chromatography (HPLC) with electrogenerated chemiluminescence as the detector.

Signal Word

Danger

Hazard Classifications

Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

Target Organs

Central nervous system, Nervous system

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point(F)

-7.6 °F

Flash Point(C)

-22 °C

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Certificate of Analysis

Enter Lot Number to search for Certificate of Analysis (COA).

Certificate of Origin

Enter Lot Number to search for Certificate of Origin (COO).

Articles

The Utility of Headspace Grade Solvents for the Analysis of Organic Volatile Impurities

The Utility of Headspace Grade Solvents for the Analysis of Organic Volatile Impurities

Protocols

GC Analysis of Total Petroleum Hydrocarbons (TPH) on SLB®-5ms

Separation of Hexane; Heptane; Octane; Nonane; Decane; Undecane; Dodecane; Tetradecane; Hexadecane; Octadecane; Eicosane; Tetracosane; Octacosane; Dotriacontane; Hexatriacontane; Tetracontane; Tetratetracontane

GC Analysis of Class 2 Residual Solvents on OVI-G43

GC Analysis of Class 2 Residual Solvents on OVI-G43

GC Analysis of Hydrocarbons in Gasoline on Petrocol® DH

Protocol for GC Analysis of Hydrocarbons in Gasoline on Petrocol® DH

GC Analysis of Hydrocarbons in Gasoline on Equity®-1 (15 m x 0.10 mm I.D., 0.10 μm), Fast GC Analysis

-Xylene; Nonane; Propylbenzene; Mesitylene; 1,2,4-Trimethylbenzene; 1,2,3-Trimethylbenzene; 1,3-Diethylbenzene; 1,4-Dimethyl-2-ethylbenzene; 1,2-Dimethyl-4-ethylbenzene; Durene; 1,2,3,5-Tetramethylbenzene; 1,2,3,5-Tetramethylbenzene; 2-Methylnaphthalene (β)

See All