Przejdź do zawartości
Merck

24010

Supelco

SP®-2250 Capillary GC Column

L × I.D. 30 m × 0.25 mm, df 0.20 μm

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
41115710
eCl@ss:
32119290

Materiały

fused silica

agency

meets requirements for USP G3

Parametry

0-250 °C temperature (isothermal or programmed)

Wartość beta

313

df

0.20 μm

metody

gas chromatography (GC): suitable

dł. × śr. wewn.

30 m × 0.25 mm

grupa aktywna macierzy

Non-bonded; poly(50% phenyl/50% methyl siloxane) phase

typ kolumny

capillary intermediate polar

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Opis ogólny

Application: The SP-2250 column is a non-bonded 50% phenyl polymer. It is highly effective for the analysis of polar compounds.
USP Code: This column meets USP G3 requirements.
Phase:
  • Non-bonded
  • Poly(50% phenyl/50% methyl siloxane)
Temp. Limits:
  • 0 °C to 250 °C (isothermal or programmed)

Zastosowanie

Capillary column coated with SP®-2250 (methyl silicone-phenyl silicone, 1:1) stationary phase may be used in gas chromatographic analysis of azaarenes (benzacridines and dibenzacridines).

Inne uwagi

We offer a variety of chromatography accessories including analytical syringes

Informacje prawne

SP is a registered trademark of Sigma-Aldrich Co. LLC
Ta strona może zawierać tekst przetłumaczony maszynowo.

Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

D F Tomkins
Journal - Association of Official Analytical Chemists, 70(6), 1056-1058 (1987-11-01)
An isothermal gas chromatographic method for measuring alachlor in Micro-Tech (microencapsulated) formulations was tested by 5 collaborators. The samples were prepared in acetone, and alachlor was determined using a gas chromatographic column of 10% SP-2250 on 100-120 mesh Supelcoport. Di-n-pentylphthalate
D J Greenblatt et al.
Anesthesiology, 55(2), 176-179 (1981-08-01)
Plasma midazolam concentrations following single therapeutic doses can be quantitated using electron-capture gas-liquid chromatography. After addition of a benzodiazepine analogue as an internal standard, samples are extracted with benzeneisoamyl alcohol (98.5:1.5). The organic extract is evaporated to dryness, reconstituted, and
J E Wallace et al.
Clinical chemistry, 25(7), 1296-1300 (1979-07-01)
We describe the use of electron-capture gas chromatography or reversed-phase "high-performance" liquid chromatography for concurrent analysis for diazepam and nordiazepam in serum. In the gas-chromatographic analysis our use of a new chemically deactivated stationary liquid phase, SP 2250-DB (Supelco, Inc.)
V Gambaro et al.
Journal of analytical toxicology, 6(6), 321-323 (1982-11-01)
The gas chromatographic identification of barbiturates isolated from biological material is not optimal, and due to their polar nature, it is difficult to obtain good resolution on most columns. To improve resolution, flash alkylation appeared to be a reasonable alternative.
D Courtot
British journal of sports medicine, 10(3), 143-146 (1976-10-01)
At the request of the Service des Haras, our laboratory works on the toxicological problems of the sport-horse. These studies have resulted in the setting up of an anti-doping control for equestrian competitions of various types, not only flat racing.

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej