Przejdź do zawartości
Merck

370037

Supelco

Poly(methyl methacrylate)

analytical standard, for GPC, average Mw 97,000 (Typical), average Mn 46,000 (Typical)

Synonim(y):

PMMA, Poly(methacrylic acid methyl ester)

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Wzór liniowy:
[CH2C(CH3)(CO2CH3)]n
Numer CAS:
Numer MDL:
Kod UNSPSC:
41116107
Identyfikator substancji w PubChem:
NACRES:
NA.24

klasa czystości

analytical standard
for GPC

Poziom jakości

temp. samozapłonu

580 °F

masa cząsteczkowa

average Mn 46,000 (Typical)
average Mw 97,000 (Typical)

metody

gel permeation chromatography (GPC): suitable

rozpuszczalność

H2O: insoluble

gęstość

1.200 g/cm3

format

neat

InChI

1S/C5H9O2/c1-4(2)5(6)7-3/h1-3H3

Klucz InChI

PMAMJWJDBDSDHV-UHFFFAOYSA-N

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Kod klasy składowania

11 - Combustible Solids

Klasa zagrożenia wodnego (WGK)

nwg

Środki ochrony indywidualnej

Eyeshields, Gloves, type N95 (US)


Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Pleural infection 55 years after plombage for pulmonary tuberculosis.
Qian-kun Chen et al.
Asian cardiovascular & thoracic annals, 21(1), 100-100 (2013-02-23)
Gursukhman S Sidhu et al.
Journal of neurosurgery. Spine, 19(1), 61-70 (2013-05-07)
The authors endeavor to highlight the surgical management of severe neurological deficit resulting from cement leakage after percutaneous vertebroplasty and to systematically review the literature on the management of this complication. A patient presented after a vertebroplasty procedure for traumatic
S A Bini et al.
The bone & joint journal, 95-B(3), 367-370 (2013-03-02)
We evaluated the impact of pre-coating the tibial component with polymethylmethacrylate (PMMA) on implant survival in a cohort of 16 548 primary NexGen total knee replacements (TKRs) in 14 113 patients. In 13 835 TKRs a pre-coated tray was used
Kariem Mostafa Al Batouty et al.
The journal of adhesive dentistry, 15(2), 161-166 (2013-03-28)
To compare the push-out bond strength of a new glass fiber root canal filling material to that of Resilon/ Epiphany, EndoREZ, and gutta-percha/AH Plus root canal filling materials. Sixty roots were randomly divided into four groups (n = 15) according
Patrick M Honore et al.
ASAIO journal (American Society for Artificial Internal Organs : 1992), 59(2), 99-106 (2013-02-27)
In recent years, after all the attention has been focused on the dose for continuous renal replacement therapy (CRRT) in sepsis and systemic inflammation response syndrome (SIRS), the relatively negative results of all those studies did urge our expectations on

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej