MHSTCMAG-70KPMX
MILLIPLEX® Mouse High Sensitivity T Cell Premixed Panel - Immunology Multiplex Assay
Simultaneous analyze low levels of cytokine and chemokine biomarker with the High Sensitivity Bead-Based Multiplex Assays using the Luminex technology, in mouse serum, plasma and cell culture samples.
Synonim(y):
Luminex® Mouse Immunology Panel, Millipore Mouse Immunology Panel, Mouse Immunology Protein Multiplex Assay
About This Item
Polecane produkty
Poziom jakości
reaktywność gatunkowa
mouse
producent / nazwa handlowa
Milliplex®
assay range
accuracy: 82-102%
sensitivity: 0.26-11.14 pg/mL
standard curve range: 0.10-400 pg/mL
(IL-4)
standard curve range: 0.49-2,000 pg/mL
(IFNγ)
standard curve range: 0.49-2,000 pg/mL
(IL-17A)
standard curve range: 0.49-2,000 pg/mL
(IL-7)
standard curve range: 0.49-2,000 pg/mL
(TNFα)
standard curve range: 0.73-3,000 pg/mL
(KC/GROα/CXCL1)
standard curve range: 0.98-4,000 pg/mL
(IL-2)
standard curve range: 0.98-4,000 pg/mL
(IL-5)
standard curve range: 0.98-4,000 pg/mL
(IL-6)
standard curve range: 1.34-5,500 pg/mL
(IL-10)
standard curve range: 2.93-12,000 pg/mL
(IL-12 (p70))
standard curve range: 3.17-13,000 pg/mL
(MCP-1/CCL2)
standard curve range: 3.42-14,000 pg/mL
(IL-13)
standard curve range: 3.91-16,000 pg/mL
(IL-1α)
standard curve range: 3.91-16,000 pg/mL
(IL-1β)
standard curve range: 6.1-25,000 pg/mL
(GM-CSF)
standard curve range: 7.32-30,000 pg/mL
(MIP-2/CXCL2)
standard curve range: 9.77-40,000 pg/mL
(LIX)
inter-assay cv: <15%
intra-assay cv: <10%
metody
multiplexing: suitable
kompatybilność
configured for Premixed
metoda wykrywania
fluorometric (Luminex xMAP)
Warunki transportu
ambient
Opis ogólny
Low levels of inflammation are involved in many clinical and sub-clinical disease states, such as autoimmune disease, cardiovascular disease, diabetes, neurological disorders, and cancer. Measuring picogram levels of cytokines, therefore, is critical for understanding the pathogenesis of these diseases.
Panel Type: Cytokines/Chemokines
Specyficzność
There is no detectable cross-reactivity within the panel.
Zastosowanie
- Analytes: GM-CSF, IFNγ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-10, IL-12 (p70), IL-13, IL-17A, KC/CXCL1, LIX, MCP-1, MIP-2, TNF-α
- Recommended Sample type: serum, plasma, tissue culture or other media
- Recommended Sample dilution: neat or 1:2 diluted serum or plasma
- Assay Run Time: Overnight
- Research Category: Inflammation & Immunology
- Research Subcategory: Immune Response Metabolic Disorders Chronic Inflammatory Disease Cardiovascular Disease
Przechowywanie i stabilność
Inne uwagi
Informacje prawne
Oświadczenie o zrzeczeniu się odpowiedzialności
Hasło ostrzegawcze
Danger
Zwroty wskazujące rodzaj zagrożenia
Zwroty wskazujące środki ostrożności
Klasyfikacja zagrożeń
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Organy docelowe
Respiratory Tract
Kod klasy składowania
10 - Combustible liquids
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej