Przejdź do zawartości
Merck
Wszystkie zdjęcia(1)

Key Documents

CTGR02TP1

Millipore

Aervent® 0.2 µm, Cartridge

pore size 0.2 μm, cartridge nominal length 20 in. (51 cm), Code 0 (2-222; O-rings)

Synonim(y):

Aervent CTGR Cartridge Filter 20 in. 0.2 µm Code 0

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
23151806
eCl@ss:
32031690

Materiały

PTFE
polypropylene
polypropylene support
silicone seal

Poziom jakości

sterylność

non-sterile

Kompatybilność ze sterylizacją

steam-in-place compatible

linia produktu

Aervent®

Właściwości

hydrophobic

producent / nazwa handlowa

Aervent®

Parametry

≤48 mL/min nitrogen diffusion at 970 mbar (14 psig) and 23 °C (in 70/30% IPA/water)
1.7 bar max. inlet pressure (25 psi) at 80 °C
1.8 bar max. differential pressure (25 psid) at 80 °C (Forward)
4.1 bar max. differential pressure (60 psid) (Reverse; intermittent)
4.1 bar max. inlet pressure (60 psi) (Reverse; Intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)

metody

gas filtration: suitable

Długość

20 in.

Szerokość

2.7 in.

długość nominalna kartridża

20 in. (51 cm)

Średnica

6.9 cm (2.7 in.)

powierzchnia filtracyjna

1.3 m2

zanieczyszczenia

<0.25 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction)

substancje ekstrahujące się grawimetrycznie

≤70 mg/cartridge

macierz

Aervent®

wielkość porów

0.2 μm pore size

moc wejściowa

sample type gas

punkt pęcherzykowania

≥1100 mbar (16 psig), nitrogen with 70/30% IPA/water at 23 °C

kod wkładu

Code 0 (2-222; O-rings)

Powiązane kategorie

Opis ogólny

Device Configuration: Cartridge

Cechy i korzyści

Rated for aerosol retention of a total challenge of 108–1010 plaque forming units of ΦX-174 virus particles at 85 Nm3/h (50 SCFM) per cartridge.

Opakowanie

Double Easy-Open bag

Jakość

Retains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²

Uwaga dotycząca przygotowania

Sterilization Method
150 (100 forward/50 reverse) SIP cycles of 30 min @ 145 °C
This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Komentarz do analizy

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: after 24 hours in a 70/30% IPA/water mixture at controlled room temperature
HydroCorr: ≤1.5 mL/min @ 2.6 bar (38 psig) per 20 in cartridge

Inne uwagi

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Informacje prawne

AERVENT is a registered trademark of Merck KGaA, Darmstadt, Germany
ASTM is a registered trademark of American Society for Testing and Materials
This page may contain text that has been machine translated.

Nie możesz znaleźć właściwego produktu?  

Wypróbuj nasz Narzędzie selektora produktów.


Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej