コンテンツへスキップ
Merck
  • Sensitivity enhancement in direct coupling of supported liquid membrane extractions to capillary electrophoresis by means of transient isotachophoresis and large electrokinetic injections.

Sensitivity enhancement in direct coupling of supported liquid membrane extractions to capillary electrophoresis by means of transient isotachophoresis and large electrokinetic injections.

Journal of chromatography. A (2015-03-10)
Pavla Pantůčková, Pavel Kubáň, Petr Boček
要旨

Enhanced sensitivity for determination of basic drugs in body fluids was achieved by in-line coupling of extraction across supported liquid membrane (SLM) to large electrokinetic injection and transient isotachophoresis-capillary zone electrophoresis (tITP-CZE) in commercial CZE instrument. Twelve cm long tITP plug of 300mM ammonium acetate was formed in the separation capillary just before the electrokinetic injection of acceptor solution containing nortriptyline, haloperidol and loperamide extracted across the SLM. The tITP plug ensured efficient stacking and preconcentration of the injected basic drugs due to the tITP action of ammonium and the drugs were then separated by CZE using 5.2M acetic acid as background electrolyte. No interferences were observed from highly-abundant body fluid species (NaCl and human serum albumin) due to the excellent clean-up properties of SLMs and analytical sensitivity increased up to 340 times compared to SLM extractions coupled in-line to CZE with standard hydrodynamic injections. The SLM-tITP-CZE method was characterized by good repeatability (RSDs of peak areas below 7.8%), linearity over two orders of magnitude (r(2) better than 0.994) and limits of detection (defined as 3×S/N) between 3 and 45μg/L. Interfacing of SLM extractions to CZE instrumentation was achieved by low-cost, disposable micro-extraction devices, which can be routinely prepared in every analytical laboratory. These devices eliminated sample carry-over, minimized the need for manual sample handling and ensured fully automated determination (including extraction, injection, preconcentration and separation) of the three basic drugs in 20μL of untreated body fluids.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
エチルアルコール(純粋), 200 proof, for molecular biology
Sigma-Aldrich
酢酸, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
酢酸, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
酢酸アンモニウム, ACS reagent, ≥97%
Sigma-Aldrich
塩化ナトリウム, for molecular biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
酢酸アンモニウム, ≥99.99% trace metals basis
Sigma-Aldrich
酢酸, glacial, ≥99.99% trace metals basis
Supelco
酢酸アンモニウム, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
塩化ナトリウム 溶液, 5 M in H2O, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
塩化ナトリウム 溶液, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
酢酸 溶液, suitable for HPLC
Sigma-Aldrich
酢酸, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
塩化ナトリウム, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
エタノール, JIS special grade, ≥99.5%
Sigma-Aldrich
塩化ナトリウム, BioXtra, ≥99.5% (AT)
Sigma-Aldrich
酢酸アンモニウム, for molecular biology, ≥98%
Sigma-Aldrich
酢酸アンモニウム 溶液, for molecular biology, 7.5 M
Sigma-Aldrich
エタノール, SAJ first grade, ≥99.5%
Sigma-Aldrich
塩化ナトリウム 溶液, BioUltra, for molecular biology, ~5 M in H2O