コンテンツへスキップ
Merck

53825-U

Supelco

Ascentis® Express 90 Å C18 (2.7 μm) HPLC Columns

L × I.D. 15 cm × 2.1 mm, HPLC Column

別名:

コアシェル(SPP)フューズドコア C18 HPLC カラム

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
41115700
eCl@ss:
32110501
NACRES:
SB.52

product name

Ascentis® Express C18, 2.7 µm HPLCカラム, 2.7 μm particle size, L × I.D. 15 cm × 2.1 mm

物質

stainless steel column

品質水準

認証

suitable for USP L1

製品種目

Ascentis®

特徴

endcapped

メーカー/製品名

Ascentis®

包装

1 ea of

パラメーター

60 °C temp. range
600 bar max. pressure (9000 psi)

テクニック

HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable

L × 内径

15 cm × 2.1 mm

表面積

135 m2/g

不純物

<5 ppm metals

マトリックス

Fused-Core particle platform
superficially porous particle

マトリックス活性基

C18 (octadecyl) phase

粒径

2.7 μm

ポアサイズ

90 Å

使用pH

2-9

アプリケーション

food and beverages

分離法

reversed phase

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

Ascentis Express HPLC カラムは、Fused-Core® 粒子技術により、低背圧を維持しながら、サブ-2 μm 粒子を高速、且つ高効率で提供することができます。高効率と低背圧の組合せがUPLC® (又は他の超高圧システム) のユーザー、並びに従来型HPLCのユーザーの助けになります。
この新カラム技術についての更なる情報については、Ascentis Expressのホームページにアクセスを。

法的情報

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Fused-Core is a registered trademark of Advanced Materials Technology, Inc.
UPLC is a registered trademark of Waters

保管分類コード

11 - Combustible Solids

WGK

WGK 3

引火点(°F)

Not applicable

引火点(℃)

Not applicable


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

53825-U:


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

Silvia Jakabová et al.
Journal of chromatography. A, 1232, 295-301 (2012-03-07)
Hyoscyamine (atropine) and scopolamine are the predominant tropane alkaloids in the Datura genus, occurring in all plant organs. The assessment of the alkaloid content of various plant parts is essential from the viewpoint of medical use, but also as a
Judy Stone
Methods in molecular biology (Clifton, N.J.), 1378, 301-320 (2015-11-26)
Serum from bar-coded tubes, and then internal standard, are pipetted to 96-well plates with an 8-channel automated liquid handler (ALH). The first precipitation reagent (methanol:ZnSO4) is added and mixed with the 8-channel ALH. A second protein precipitating agent, 1 %
Babu Rao Chandu et al.
SpringerPlus, 2(1), 194-194 (2013-06-07)
A bioequivalence study was proved of generic Febuxostat 80 mg tablets (T) in healthy volunteers.For this purpose, Authors developed a simple, sensitive, selective, rapid, rugged and reproducible liquid chromatography-tandem mass spectrometry method for the quantification of Febuxostat (FB) in human
Petra Šilarová et al.
Food chemistry, 237, 471-480 (2017-08-03)
The degradation of catechins and other phenolics in green tea infusions were monitored using fast HPLC/MS separation. The final separation was performed within 2.5min using Ascentis Express C18 column (50mm×2.1mm i.d.) packed with 2μm porous shell particles. Degradation was studied
Pankaj Partani et al.
Journal of chromatographic science, 54(8), 1385-1396 (2016-05-27)
A liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of simvastatin (SV) and simvastatin acid (SVA) in human plasma. To improve assay sensitivity and achieve simultaneous analysis, SVA monitored in (-)ESI (electrospray ionization) mode within

資料

Supel Tox AflaZea SPE produced exceptional analyte recoveries with good reproducibility for all aflatoxins while requiring less than half the sample volume required by competing products.HPLC analysis of all spiked samples after SPE cleanup showed that all compared SPE cartridges effectively eliminate interferences.

Derivatization of Aliphatic Amines - Results from the Supelco Ascentis Express column show higher peak resolution, and improved peak shapes than typical chromatograms.

Sigma-Aldrich presents an article on serum lipidomics profiling using an Ascentis Express Fused-Core C18 column.

Ascentis® Express C18 is the first choice when starting a new separation method.

プロトコル

This selective and fast MIP extraction procedure allows trace amounts of patulin to be easily detected in apple juice, with high analyte recovery and reproducibility.

Better Tools for Fast and Convenient Patulin Analysis

Fast method for the cleanup, analysis, and quantification of aflatoxin M1 in milk samples to EU regulatory standards (0.025 μg/kg).

Separation of Irgasan, ≥97.0% (HPLC)

すべて表示

Chromatograms

application for HPLCapplication for HPLC

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)