1,2-ジブロモエタン 溶液

certified reference material, 200 μg/mL in methanol

別名:

エチレンジブロミド

ログイン組織・契約価格を表示する


About This Item

実験式(ヒル表記法):
C2H4Br2
CAS番号:
分子量:
187.86
EC Number:
MDL番号:
UNSPSCコード:
77101502
PubChem Substance ID:
NACRES:
NA.24

グレード

certified reference material
TraceCERT®

製品種目

TraceCERT®

CofA

current certificate can be downloaded

包装

ampule of 1 mL

濃度

200 μg/mL in methanol

テクニック

HPLC: suitable
gas chromatography (GC): suitable

アプリケーション

agriculture
environmental

フォーマット

single component solution

保管温度

2-30°C

SMILES記法

BrCCBr

InChI

1S/C2H4Br2/c3-1-2-4/h1-2H2

InChI Key

PAAZPARNPHGIKF-UHFFFAOYSA-N

類似した製品をお探しですか? 訪問 製品比較ガイド

アプリケーション

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

その他情報

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

法的情報

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

ピクトグラム

FlameSkull and crossbonesHealth hazard

シグナルワード

Danger

危険有害性情報

危険有害性の分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

ターゲットの組織

Eyes,Central nervous system

保管分類コード

3 - Flammable liquids

WGK

WGK 2

引火点(°F)

51.8 °F - closed cup

引火点(℃)

11 °C - closed cup

個人用保護具 (PPE)

Eyeshields, Faceshields, Gloves


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

消防法

第4類:引火性液体
アルコール類
危険等級II

労働安全衛生法名称等を表示すべき危険物及び有害物

名称等を表示すべき危険物及び有害物

労働安全衛生法名称等を通知すべき危険物及び有害物

名称等を通知すべき危険物及び有害物

Jan Code

48880-U:4548173161617


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

James K Henderson et al.
Journal of contaminant hydrology, 108(1-2), 29-45 (2009-06-19)
An analytical model is used to simulate the effects of partial source removal and plume remediation on ethylene dibromide (EDB) and 1,2-dichloroethane (1,2-DCA) plumes at contaminated underground storage tank (UST) sites. The risk posed by EDB, 1,2-DCA, and commingled gasoline
Katerina Papezová et al.
Journal of chromatography. A, 1150(1-2), 327-331 (2006-10-03)
Substrate inhibition is a common phenomenon in enzyme kinetics. We report here for the first time its study by a combination of the electrophoretically mediated microanalysis (EMMA) methodology with a partial filling technique. In this setup, the part of capillary
Annamaria Colacci et al.
Toxicology in vitro : an international journal published in association with BIBRA, 25(6), 1183-1190 (2011-06-16)
Cell transformation assays (CTAs) are currently regarded as the only possible in vitro alternative to animal testing for carcinogenesis studies. CTAs have been proposed as screening tests for the carcinogenic potential of compounds that have no evidence of genotoxicity but
Genotoxic effects of 1,2-dibromoethane and 1,2-dichloroethane.
U Rannug
Mutation research, 76(3), 269-295 (1980-11-01)
James K Henderson et al.
Environmental science & technology, 42(3), 864-870 (2008-03-08)
Field evidence from underground storage tank sites where leaded gasoline leaked indicates the lead scavengers 1,2-dibromoethane (ethylene dibromide, or EDB) and 1,2-dichloroethane (1,2-DCA) may be present in groundwater at levels that pose unacceptable risk. These compounds are seldom tested for

プロトコル

US EPA Method TO-17: GC Analysis of Volatiles on VOCOL® after Collection/Desorption using Air Toxics Tube

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.