About This Item

化学式:
NH4OH
CAS番号:
分子量:
35.05
Beilstein:
3587154
MDL番号:
UNSPSCコード:
12352106
eCl@ss:
38060103
PubChem Substance ID:

グレード

ACS reagent

蒸気密度

1.2 (vs air)

蒸気圧

115 mmHg ( 20 °C)

形状

liquid

expl. lim.

27 %

濃度

28.0-30.0% NH3

不純物

MnO4- reducers, passes test
≤0.002% CO2

強熱残分

≤0.002%

密度

0.9 g/mL at 25 °C (lit.)

微量陰イオン

chloride (Cl-): ≤0.5 ppm
nitrate (NO3-): ≤2 ppm
phosphate (PO43-): ≤2 ppm
sulfate (SO42-): ≤2 ppm

微量陽イオン

Fe: ≤0.2 ppm
heavy metals (as Pb): ≤0.5 ppm

SMILES記法

[NH4+].[OH-]

InChI

1S/H3N.H2O/h1H3;1H2

InChI Key

VHUUQVKOLVNVRT-UHFFFAOYSA-N

類似した製品をお探しですか? 訪問 製品比較ガイド

ピクトグラム

CorrosionExclamation markEnvironment

シグナルワード

Danger

危険有害性情報

危険有害性の分類

Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1 - Skin Corr. 1 - STOT SE 3

ターゲットの組織

Respiratory system

保管分類コード

8B - Non-combustible corrosive hazardous materials

WGK

WGK 2

引火点(°F)

Not applicable

引火点(℃)

Not applicable


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

毒物及び劇物取締法

劇物

労働安全衛生法名称等を表示すべき危険物及び有害物

名称等を表示すべき危険物及び有害物

労働安全衛生法名称等を通知すべき危険物及び有害物

名称等を通知すべき危険物及び有害物

Jan Code

320145-1L:
320145-2.5L:4548173134635
320145-6X500ML:4548173134666
320145-VAR:
320145-2.5L-PW:
320145-EW:
320145-500ML:4548173134642
320145-500ML-PW:
320145-6X2.5L-PW:
320145-6X2.5L:4548173134659
320145-BULK:
320145-6X500ML-PW:


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

この製品を見ている人はこちらもチェック

Courtney R Sullivan et al.
Molecular neurobiology, 56(6), 4492-4517 (2018-10-20)
We utilized a cell-level approach to examine glycolytic pathways in the DLPFC of subjects with schizophrenia (n = 16) and control (n = 16) and found decreased mRNA expression of glycolytic enzymes in pyramidal neurons, but not astrocytes. To replicate these novel bioenergetic findings
Konstantin Chingin et al.
Analytical chemistry, 84(15), 6856-6862 (2012-07-12)
We introduce an online multiple-junction capillary isoelectric focusing fractionator (OMJ-CIEF) for separation of biological molecules in solution by pI. In OMJ-CIEF, the separation capillary is divided into seven equal sections joined with each other via tubular Nafion membrane insertions. Each
Ciceron Ayala-Orozco et al.
ACS nano, 8(6), 6372-6381 (2014-06-04)
Au nanoparticles with plasmon resonances in the near-infrared (NIR) region of the spectrum efficiently convert light into heat, a property useful for the photothermal ablation of cancerous tumors subsequent to nanoparticle uptake at the tumor site. A critical aspect of
Enrique Cequier et al.
Analytica chimica acta, 845, 98-104 (2014-09-10)
Organophosphate triesters are common flame retardants used in a wide variety of consumer products from which they can migrate and pollute the indoor environment. Humans may thus be continuously exposed to several organophosphate triesters which might be a risk for
Aurélie Periat et al.
Journal of chromatography. A, 1356, 211-220 (2014-07-16)
In this study, the influence of electrospray ionization (ESI) source design on the overall sensitivity achieved in hydrophilic interaction chromatography (HILIC) and reversed phase liquid chromatography (RPLC), was investigated. State-of-the-art triple quadrupole mass analyzers from AB Sciex, Agilent Technologies and

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)