おすすめの製品
product name
Amberlite™ XAD4,
形状
beads
自己発火温度
800 °F
テクニック
LPLC: suitable
表面積
750 m2/g
損失
~55% loss on drying, 110 °C
マトリックス
styrene-divinylbenzene
マトリックス活性基
polymer
粒径
20-60 mesh
ポアサイズ
~0.98 mL/g pore volume
100 Å mean pore size
密度
1.02 g/mL (true wet)(lit.)
1.08 g/mL (skeletal)(lit.)
分離法
reversed phase
類似した製品をお探しですか? 訪問 製品比較ガイド
詳細
疎水性や極性の相互作用を介してイオン分子種を吸着、放出する非イオン性マクロレティキュラ-樹脂;通常、アイソクラティック条件下で使用されます。
アプリケーション
小さな疎水性化合物、界面活性剤、医薬品製造、フェノ-ル類、塩素有機物質、農薬除去および回収、水系食品流動時の有機物質除去用の多環芳香族吸着剤
Amberlite XAD-4 has been used in the clean-up procedure prior to high performance liquid chromatography-evaporative laser scattering detector (HPLC-ELSD) analysis of mycotoxin fumonisins in corn products. It has also been used as a solid sorbent to trap imidacloprid and its metabolite 6-chloronicotinic acid from greenhouse air prior to their determination by HPLC coupled to diode array detector (DAD).
その他情報
粒径は2種類あります:
Mesh 20-60 は、製品番号20276、10358、XAD4です。
Mesh 20-50は、製品番号06444です。
Mesh 20-60 は、製品番号20276、10358、XAD4です。
Mesh 20-50は、製品番号06444です。
法的情報
Amberlite is a trademark of DuPont de Nemours, Inc.
保管分類コード
11 - Combustible Solids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
個人用保護具 (PPE)
Eyeshields, Gloves, type N95 (US)
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
06444-BULK:
06444-VAR:
06444-100G:
06444-500G:
この製品を見ている人はこちらもチェック
Analysis of mycotoxin fumonisins in corn products by high-performance liquid chromatography coupled with evaporative light scattering detection.
Food Chemistry, 107(2), 970-976 (2008)
Bioresource technology, 102(17), 8035-8039 (2011-07-09)
The present work proposes the use of Pleurotus ostreatus immobilized on Amberlite XAD-4 as new biosorbent in trace metal determination. The effects of experimental parameters, such as "pH and flow rate of sample solution, amount of solid phase, eluent type
Ecotoxicology and environmental safety, 73(7), 1620-1628 (2010-08-06)
The tannery effluents at Kanpur (India) have been in use for irrigation since last many years, polluting soil directly while ground water and food crops indirectly. Gas chromatography-mass spectrometric analysis of the test samples revealed the presence of organic compounds
Environmental monitoring and assessment, 185(3), 2691-2704 (2012-07-20)
Nascent Amberlite XAD-4 has been used as the polymeric support for the synthesis of a stable extractor of metal ions, by incorporating phthalic acid through azo bridging. Elemental analyses and infra-red spectral and thermal studies were carried out for its
Journal of hazardous materials, 171(1-3), 815-819 (2009-07-18)
Fluoride in drinking water above permissible level is responsible for human being affected by skeletal fluorosis. In this study, Amberlite XAD-4 has been modified by introducing amino group onto the aromatic ring for its application in fluoride remediation. Characterization of
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)