コンテンツへスキップ
Merck

10357

Supelco

Amberlite XAD®-2

pkg of 500 g

ログイン組織・契約価格を表示する


About This Item

CAS番号:
UNSPSCコード:
23151817

形状

beads (small)

品質水準

包装

pkg of 500 g

利用可能性

not available in (Currently experiencing backorder delays due to raw material supply disruption)

テクニック

HPLC: suitable
LPLC: suitable

表面積

~300 m2/g

マトリックス

styrene-divinylbenzene (macroreticular)

マトリックス活性基

polymer

粒径

20-60 mesh

ポアサイズ

~0.65 mL/g pore volume
90 Å mean pore size

密度

1.02 g/mL at 25 °C (true wet)(lit.)
1.08 g/mL at 25 °C (skeletal)(lit.)

分離法

reversed phase

保管温度

2-8°C

InChI

1S/C24H27NO5/c1-24(2,3)30-22(27)13-12-16(14-26)25-23(28)29-15-21-19-10-6-4-8-17(19)18-9-5-7-11-20(18)21/h4-11,14,16,21H,12-13,15H2,1-3H3,(H,25,28)/t16-/m0/s1

InChI Key

BCIPGSZQUDLGSY-INIZCTEOSA-N

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

Amberlite XAD-2はスチレン-ジビニルベンゼン樹脂の疎水性コポリマーで、長い精製プロセスを要し、吸着剤として使用されます。Amberlite XAD-2樹脂は、芳香族性基および疎水性基のサイズに依存して、低エネルギー物理的相互作用を通して有機化合物を吸着します。
疎水性や極性の相互作用を介してイオン分子種を吸着、放出する非イオン性マクロレティキュラ-樹脂;通常、アイソクラティック条件下で使用されます。
仕様:

アプリケーション

Amberlite XAD®-2は、Soxhlat抽出法
  • を使用した有機塩素系化合物の抽出において
    • 吸着材として使用されました。また、
    • 吸着クロマトグラフィーを行うためにHPLC分析用カラムクロマトグラフィーを使用したハチミツサンプルの抽出において吸着材として使用されました。
    分子量20,000以下の疎水性化合物用の多環芳香族吸着樹脂:フェノ-ル、有機物質除去、界面活性剤、芳香族化合物、抗生物質の回収触媒または金属除去の担体として使用できます。精製された米EPAバ-ジョンについては、Supelpak-2およびSupelpak-2Bを参照してください。

    法的情報

    Amberlite is a trademark of DuPont de Nemours, Inc.
    XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow

    関連製品

    製品番号
    詳細
    価格

    保管分類コード

    11 - Combustible Solids

    WGK

    WGK 3

    引火点(°F)

    Not applicable

    引火点(℃)

    Not applicable

    個人用保護具 (PPE)

    Eyeshields, Gloves, type N95 (US)


    Choose from one of the most recent versions:

    試験成績書(COA)

    Lot/Batch Number

    Don't see the Right Version?

    If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

    以前この製品を購入いただいたことがある場合

    文書ライブラリで、最近購入した製品の文書を検索できます。

    文書ライブラリにアクセスする

    この製品を見ている人はこちらもチェック

    I Martos et al.
    Journal of agricultural and food chemistry, 48(5), 1498-1502 (2000-05-23)
    European Eucalyptus honeys showed a common and characteristic HPLC profile in which the flavonoids myricetin (3,5,7,3',4', 5'-hexahydroxyflavone), tricetin (5,7,3',4',5'-pentahydroxyflavone), quercetin (3,5,7,3',4'-pentahydroxyflavone), luteolin (5,7,3', 4'-tetrahydroxyflavone), and kaempferol (3,5,7, 4'-tetrahydroxyflavone) were identified. Their contents, and relative amounts, in the analyzed honey samples
    M Tamura et al.
    The Journal of biological chemistry, 260(17), 9672-9677 (1985-08-15)
    Na+,K+-ATPase inhibitors have been found to exist in acutely saline-infused hog plasma, which also inhibit the specific binding of ouabain to Na+,K+-ATPase and the binding of digoxin to specific anti-digoxin antibody. Two of these inhibitors were purified by a combination
    Trapping efficiency of polyurethane foam and Amberlite XAD-2 for various organochlorine compounds
    Nerin, C., et al.
    Fresenius Journal of Analytical Chemistry, 352, 609-611 (1995)
    Mario Vincenzo Russo et al.
    Analytical and bioanalytical chemistry, 404(5), 1517-1527 (2012-07-05)
    This paper shows an analytical methodology based on solid-phase extraction by XAD-2 adsorbent and gas chromatography (GC) coupled with nitrogen-phosphorus (NPD) and ion-trap mass spectrometry detectors (ITMS) in negative chemical ionization (NCI) mode analyses for investigating organophosphorus pesticides (OPs) at
    Feng Xiao et al.
    Journal of colloid and interface science, 368(1), 505-511 (2011-12-14)
    Amberlite XAD resins have been employed to a great extent as the sorbent for removing or concentrating organic compounds from different matrices. We present for the first time a systematic study on the sorption of perfluorochemical (PFC) surfactants, an emerging

    関連コンテンツ

    Low pressure liquid chromatography (LPLC) operates at low pressures, using a pump to drive the mobile phase onto the column.

    低圧液体クロマトグラフィー(LPLC)は、低圧で作動するクロマトグラフィー技術の1つで、移動相はポンプの働きにより固定相が充てんされたカラム内を移動します。

    ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

    製品に関するお問い合わせはこちら(テクニカルサービス)