おすすめの製品
物質
acrylic
polypropylene
silica filter aid
品質水準
詳細
Secondary clarification of bioreactor harvests, post centrate harvest
特徴
hydrophilic
メーカー/製品名
Millistak+®
パラメーター
2.1 bar max. differential pressure (30 psid) at 25 °C (Forward)
30 psid max. differential pressure (2.1 bar) at 37 °C (Reverse)
30 psid max. differential pressure (2.1 bar) at 4 °C (Forward)
30 psid max. inlet pressure (2.1 bar) at 25 °C
H
140 mm
5.5 in. (14 cm)
L
8.6 in. (22 cm)
ろ過面積
0.014 m2
不純物
<0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
入力
sample type liquid
導電率
19.34-53.2 μS/cm at 25 °C (product water)
フィルターグレード
X0SP
類似した製品をお探しですか? 訪問 製品比較ガイド
詳細
The Millistak+® Pod Depth Filter is a synthetic depth filter providing a cleaner and more consistent depth filtration media over current diatomaceous earth (DE) and cellulose (CE) based filter offerings. This unit, featured in a Lab Scale Pod format with a X0SP media grade, supports primary and secondary clarification as well as downstream filtration applications.
アプリケーション
Secondary clarification of bioreactor harvests, post centrate harvest
特徴および利点
Synthetic materials of construction
Lot to lot consistency for successful development and implementation of robust clarification processes
Depth filter media formulation & design
Disposable Pod device
- Reduce TOC extractables and pre-use flush volume requirements by 50%
- No beta glucans to interfere with limulous amoebocyte lysate (LAL) testing for bacterial endotoxins
Lot to lot consistency for successful development and implementation of robust clarification processes
Depth filter media formulation & design
- Provide as much as two times the filtration capacity with equivalent filter retention properties over commercial DE-based benchmarks
- Improved HCP impurity clearance
Disposable Pod device
- Flexible, modular format offers scalability from 5 to 12,000 liters or more
- Robust device format; easy to use and set up
規格
Filter Grade: X0SP
Trace metals were measured post pure water flush of 50 L/m2 of surface area and 24-hour static soak in pure water. Values based on average of metals extractibles data from three separate uPod device lots. The analysis was made by ICP-MS. The devices were not autoclaved.
調製ノート
Sterilization Method
1 autoclave cycle of 60 min @ 123 ºC, filtration performance may be impacted. Recommended for post use contamination only.
1 autoclave cycle of 60 min @ 123 ºC, filtration performance may be impacted. Recommended for post use contamination only.
アナリシスノート
Product Water Conductivity at 25°C: post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 10 liters per ft2 (100 L/m2) of media surface area