コンテンツへスキップ
Merck
すべての画像(1)

主要文書

MTGR65000

Millipore

Aervent® 50 Capsuleフィルター

pore size 0.2 μm

別名:

EPA Est. 041237-FRA-001

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
23151806
eCl@ss:
32031690
NACRES:
NB.24

物質

PTFE membrane
polypropylene
polypropylene housing

品質水準

無菌性

non-sterile

滅菌適合性

gamma compatible

製品種目

Aervent®

特徴

hydrophobic

メーカー/製品名

Aervent®

パラメーター

2.1 bar max. differential pressure at 25 °C
4.1 bar max. inlet pressure (60 psi) at 25 °C

テクニック

gas filtration: suitable

L

5.3 cm (2.1 in.)

W

2.4 in.

直径

6.2 cm (2.4 in.)

ろ過面積

19.6 cm2

不純物

≤0.5 EU/mL (LAL test, Aqueous extraction)

重量分析抽出物

≤1.0 mg

Matrix

Aervent®

ポアサイズ

0.2 μm pore size

泡立ち点

≥1100 mbar (16 psig), nitrogen with 60/40% IPA/water at 23 °C

フィッティング

3 mm (1/8 in.) male NPT inlet/outlet connection (One side)
inlet/outlet hose for 6.5-9.5 mm I.D. silicone tubing (Other side)

輸送温度

ambient

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

This Aervent® hydrophobic Capsule filter contain a 50 mm Aervent PTFE membrane in a bi-directionally supported polypropylene casing. This sterilizing-grade filter, with a 0.2 μm pore size and 19.6 cm2 filtration area, is designed for critical small scale gas line and air venting applications. The hydrophobic Aervent PTFE membrane within MTGR65000 provides high flow rates and throughput, low extractables and particle shedding, and broad chemical compatibility. For traceability and easy identification, each Aervent-50 filter is hot stamped with its catalogue number and lot number. Each Aervent® Capsule Filter is integrity tested during manufacture.

アプリケーション

Typical Applications
  • Sterile venting of vessels and carboys
  • Autoclave vacuum break lines
  • Low volume sterile filtration of non-aqueous fluids
  • Small fermenter inlet and exhaust gas filtration

アナリシスノート

Gravimetric Extractables: in 70/30 % IPA/water

その他情報

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

法的情報

AERVENT is a registered trademark of Merck KGaA, Darmstadt, Germany

試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)