コンテンツへスキップ
Merck

A-LMPN100

Sigma-Aldrich

AnteoBind Micro

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
12352200
NACRES:
NA.22

形状

liquid

利用可能性

not available in Japan

詳細

AnteoBind Micro was developed for binding antibodies and other proteins to magnetic particles greater than 1 μm in size. It forms strong multi-valent interactions with almost any electron donating groups including carboxylic acids. Once proteins are added, AnteoBind activated particles rapidly form very strong but gentle binding interactions.
AnteoBind Micro has been used to stably activate many particles. Examples include: M-270 Dynabeads®, Bangs ProMag®, JSR MS300 Carboxyl and Estapor® M1-200/20.
AnteoBind Micro has many advantages over existing methods such as EDC/NHS chemistry or alternative ″pre-activated″ methods such as Epoxy or Tosyl. AnteoBind is water based and replaces the dry chemicals you would use with the EDC method. Using AnteoBind instead of NHS/EDC chemistry can save up to 3-4 hours of lab time. Experiments have shown increased stability and functionality for antibodies and a decreased background. AnteoBind improves reproducibility between experiments by providing uniformity between surfaces. For particles from 0.5 μm to 1 μm the recommended AnteoBind product is AnteoBind Sub-Micron.

アプリケーション

Activation and coupling of particles > 1 μm in diameter

特徴および利点

  • Water based, activation and coupling reagent for particles > 1 μm in diameter
  • An alternative to traditional chemistries such as NHS/EDC methods with an easier to use AnteoBind protocol
  • Reduce reagent preparation time by 3-4 hours
  • Increase antibody functionality
  • Low background noise
  • High reproducibility between experiments

法的情報

Anteobind is a trademark of AnteoTech Ltd
Dynabeads is a registered trademark of Invitrogen Dynal AS Corp
Estapor is a registered trademark of Merck KGaA, Darmstadt, Germany
ProMag is a registered trademark of Polysciences, Inc

ピクトグラム

Health hazardCorrosion

シグナルワード

Danger

危険有害性情報

危険有害性の分類

Carc. 2 - Eye Dam. 1 - Repr. 2 - Skin Irrit. 2

保管分類コード

12 - Non Combustible Liquids

WGK

WGK 3

引火点(°F)

Not applicable

引火点(℃)

Not applicable


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

PRTR

第一種指定化学物質

労働安全衛生法名称等を表示すべき危険物及び有害物

名称等を表示すべき危険物及び有害物

労働安全衛生法名称等を通知すべき危険物及び有害物

名称等を通知すべき危険物及び有害物

Jan Code

A-LMPN100-VAR:
A-LMPN100-5ML:
A-LMPN100-BULK:


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)