Pular para o conteúdo
Merck
  • Simultaneous and high-throughput analysis of iodo-trihalomethanes, haloacetonitriles, and halonitromethanes in drinking water using solid-phase microextraction/gas chromatography-mass spectrometry: an optimization of sample preparation.

Simultaneous and high-throughput analysis of iodo-trihalomethanes, haloacetonitriles, and halonitromethanes in drinking water using solid-phase microextraction/gas chromatography-mass spectrometry: an optimization of sample preparation.

Journal of chromatography. A (2014-09-27)
Qian Luo, Xichao Chen, Zi Wei, Xiong Xu, Donghong Wang, Zijian Wang
RESUMO

When iodide and natural organic matter are present in raw water, the formation of iodo-trihalomethanes (Iodo-THMs), haloacetonitriles (HANs), and halonitromethanes (HNMs) pose a potential health risk because they have been reported to be more toxic than their brominated or chlorinated analogs. In the work, simultaneous analysis of Iodo-THMs, HANs, and HNMs in drinking water samples in a single cleanup and chromatographic analysis was proposed. The DVB/CAR/PDMS fiber was found to be the most suitable for all target compounds, although 75μm CAR/PDMS was better for chlorinated HANs and 65μm PDMS/DVB for brominated HNMs. After optimization of the SPME parameters (DVB/CAR/PDMS fiber, extraction time of 30min at 40°C, addition of 40% w/v of salt, (NH4)2SO4 as a quenching agent, and desorption time of 3min at 170°C), detection limits ranged from 1 to 50ng/L for different analogs, with a linear range of at least two orders of magnitude. Good recoveries (78.6-104.7%) were obtained for spiked samples of a wide range of treated drinking waters, demonstrating that the method is applicable for analysis of real drinking water samples. Matrix effects were negligible for the treated water samples with total organic carbon concentration of less than 2.9mg/L. An effective survey conducted by two drinking water treatment plants showed the highest proportion of Iodo-THMs, HANs, and HNMs occurred in treated water, and concentrations of 13 detected compounds ranged between the ng/L and the μg/L levels.

MATERIAIS
Número do produto
Marca
Descrição do produto

Sigma-Aldrich
Metil-terc-butil éter, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Metil-terc-butil éter, ACS reagent, ≥99.0%
Sigma-Aldrich
Metil-terc-butil éter, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Metil-terc-butil éter, reagent grade, ≥98%
Sigma-Aldrich
Nitromethane, ACS reagent, ≥95%
Sigma-Aldrich
Metil-terc-butil éter, anhydrous, 99.8%
Sigma-Aldrich
Nitromethane, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Fluorobenzene, 99%
Sigma-Aldrich
Metil-terc-butil éter, puriss. p.a., ≥99.5% (GC)
Sigma-Aldrich
1-Bromo-4-fluorobenzene, 99%
Sigma-Aldrich
Metil-terc-butil éter, reagent grade, 98%
Sigma-Aldrich
Nitromethane, suitable for HPLC, ≥96%
Supelco
Metil-terc-butil éter, analytical standard
Supelco
4-Bromofluorobenzene, analytical standard
Supelco
Metil-terc-butil éter, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Fluorobenzene, analytical standard