Pular para o conteúdo
Merck
Todas as fotos(4)

Documentos Principais

71016BC

Millipore

GDS MPX Top 6 STEC

BioControl, Molecular based PCR test for the detection of the "Top Six" non-O157 Shiga Toxigenic E. coli (STEC) in food

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41106302
NACRES:
NB.61

Nível de qualidade

prazo de validade

6‑12 mo.

fabricante/nome comercial

BioControl Systems 71016-100

temperatura de armazenamento

2-8°C

Descrição geral

GDS MPX Top 6 STEC is an automated nucleic acid amplification system for the detection of the “Top Six” non-O157 Shiga Toxigenic E. coli (STEC) in raw ground beef, raw beef trim, raw spinach, and raw mixed greens (baby lettuce and other young leafy green vegetables). The "Top Six" non-O157 STEC are defined as E. coli belonging to serogroups O103, O111, O121, O145, O26 or O45 that possess both the eae gene and at least one of the Shiga Toxin Genes stx1 or stx2. GDS MPX Top 6 STEC utilizes a proprietary IMS-based sample preparation procedure to isolate organisms belonging to 6 specific Top STEC O-serogroups (O103, O111, O121, O145, O26 and O45) prior to genetic analysis for the associated pathogenicity genes.

Características e benefícios

  • Following sample preparation with IMS against the Top 6 O groups, samples are analyzed with a single multiplex assay for the presence of (eae), stx1, and stx2
  • Single-step 10-18 h enrichment in mEHEC®, enrichment media common to all BioControl methods for E.coli O157:H7, Shiga Toxin genes, and Top STEC

Componentes

  • MPX Top STEC Amplification Tubes
  • Top 6 STEC Concentration Reagent
  • Resuspension Buffer Tq
  • Top STEC Wash Solution

Compatibilidade

BioControl GDS

Método de teste

PCR, Immunomagnetic Separation (IMS)

Informações legais

mEHEC is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogramas

Corrosion

Palavra indicadora

Warning

Frases de perigo

Declarações de precaução

Classificações de perigo

Met. Corr. 1

Código de classe de armazenamento

8A - Combustible corrosive hazardous materials

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Se precisar de ajuda, entre em contato Atendimento ao cliente

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica