Pular para o conteúdo
Merck
Todas as fotos(1)

Key Documents

KHGEG006FH3

Millipore

Cápsula Millipore Express® SHC, Opticap® XL

inlet connection diam. 3/4 in., Opticap® XL 600, pore size 0.5/0.2 μm, cartridge nominal length 6.5 in. (16.5 cm)

Sinônimo(s):

Opticap Gamma Compatible XL 600 Millipore Express SHC 0.5/0.2 μm 3/4 in. TC-9/16 in. HB

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
23151806
NACRES:
NB.24

Materiais

polyethersulfone
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap (Gamma stable)
polysulfone
silicone seal

Nível de qualidade

conformidade reg.

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

esterilidade

irradiated
non-sterile

Compatibilidade de esterilização

gamma compatible

linha de produto

Opticap® XL 600

Características

gamma compatible
hydrophilic

fabricante/nome comercial

Millipore Express®

Parâmetros

≤3.7 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

técnica(s)

sterile filtration: suitable

Comprimento

16.5 cm (6.5 in.)

Largura

2.2 in.

comprimento nominal do cartucho

6.5 in. (16.5 cm)

Diâmetro

5.6 cm (2.2 in.)

área de filtração

590 cm2

diâm. conexão de entrada

3/4 in.

L entrada para a saída

16.5 cm (6.5 in.)

diam. conexão de saída

9/16 in.

Impurezas

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

matriz

Millipore Express® SHC

pore size

0.5/0.2 μm pore size

ponto de bolha

≥4000 mbar (58 psig), air with water at 23 °C

conector

1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet hose barb
(19 mm (3/4 in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet)

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Device Configuration: Capsule

Embalagem

Double Easy-Open bag

Outras notas

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Nota de preparo

Sterilization Method
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Nota de análise

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 3.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L

Informações legais

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Exoneração de responsabilidade

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Não está encontrando o produto certo?  

Experimente o nosso Ferramenta de seleção de produtos.


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica