1.05787
HPTLC plates, Cellulose
pkg of 25 plates, plate L × W 10 cm × 10 cm, glass support
Sinônimo(s):
Cellulose TLC Plates
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Código UNSPSC:
41115711
NACRES:
NB.21
Produtos recomendados
Materiais
cellulose matrix
glass support
Nível de qualidade
Características
binder Organic Polymer
fluorescent indicator: no
embalagem
pkg of 25 plates
técnica(s)
thin layer chromatography (TLC): suitable
espessura da camada
60-110 μm
placa C × L
10 cm × 10 cm
temperatura de armazenamento
2-30°C
Categorias relacionadas
Descrição geral
25 Glass plates 10 x 10 cm
Cellulose plates are used to analyze polar substances. An organic sorbent, cellulose is perfect for separating hydrophilic substances by partition chromatography. Typical applications include the analysis of amino acids, carbohydrates, and phosphates as well as nucleic acid and nucleic acid derivatives. We offer cellulose plates in two grades: TLC for conventional and HPTLC for demanding, high-performance separations.
Aplicação
- Fast assessment of planar chromatographic layers quality using pulse thermovision method: Focuses on the quality control of cellulose HPTLC plates, ensuring the reliability of chromatographic processes in various research and industrial applications (Suszyński et al., 2014).
- High-performance thin-layer chromatographic-densitometric determination of secoisolariciresinol diglucoside in flaxseed: Utilizes cellulose HPTLC plates for precise quantification of bioactive compounds in natural products, serving the needs of the nutraceutical and pharmaceutical industries (Coran et al., 2004).
Ligação
Replaces: 5787-5; 5787
Nota de análise
Layer thickness: 60 - 110 µm
Deviation of layer thickness per plate: ≤ 30 µm
Aminoacid test
hRf-values
- L-serine, amino acid test:
20 - 30
- L-threonine, amino acid test: 30 - 40
- L-alanine, amino acid test: 35 - 45
- L-methionine, amino acid test: 55 - 65
- L-phenylalanine, amino acid test: 60 - 70
- L-leucine, amino acid test: 70 - 80
Typical value determined on a plate
Eluent: 1-Butanol/ acetone/ acetic acid/ water (35/35/7/23 v/v/v/v) twice developed
Deviation of layer thickness per plate: ≤ 30 µm
Aminoacid test
hRf-values
- L-serine, amino acid test:
20 - 30
- L-threonine, amino acid test: 30 - 40
- L-alanine, amino acid test: 35 - 45
- L-methionine, amino acid test: 55 - 65
- L-phenylalanine, amino acid test: 60 - 70
- L-leucine, amino acid test: 70 - 80
Typical value determined on a plate
Eluent: 1-Butanol/ acetone/ acetic acid/ water (35/35/7/23 v/v/v/v) twice developed
produto relacionado
Nº do produto
Descrição
Preços
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica