WHA13549204
Whatman® FF170HP Din A
sheets nitrocellulose membrane, pack of 10 sheets
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Produtos recomendados
Materiais
polyester backing
sheets nitrocellulose membrane
esterilidade
non-sterile
embalagem
pack of 10 sheets
fabricante/nome comercial
Whatman 13549204
tamanho
210 m × 297 mm
espessura
200 μm
Categorias relacionadas
Descrição geral
FF High Performance (HP) membranes are part of the AE family, which are directly cast onto a plastic film. The FFHP membranes are a result of improved membrane casting procedures, which result in enhanced intra- and inter lot consistency and sharper lines. The surface is uniform without unincorporated nitrocellulose powder and the fine structure fiber distribution provides large internal surfaces for binding proteins
Nitrocellulose membranes are a key functional part of lateral-flow assays. The membrane must provide sufficient protein binding to enable the formation of a sharp and intense capture line, but at the same time the level of nonspecific background must be low for easy interpretation of results. Nitrocellulose membranes are available in a range of wicking rates and formulations. It has long been known that the wicking rate of a membrane has a significant impact on test sensitivity.
Nitrocellulose membranes are a key functional part of lateral-flow assays. The membrane must provide sufficient protein binding to enable the formation of a sharp and intense capture line, but at the same time the level of nonspecific background must be low for easy interpretation of results. Nitrocellulose membranes are available in a range of wicking rates and formulations. It has long been known that the wicking rate of a membrane has a significant impact on test sensitivity.
Características e benefícios
A backed and highly consistent membrane for use with low viscosity samples in a lateral flow assay.
- Exceptional intra- and inter-lot consistency as demonstrated by a coefficient of variation (CV) for capillary rise of < 10%.</LI>Improved assay consistency and reproducible limit of detection.
- Reduced assay optimization costs, compared to a less consistent membrane.
Informações legais
Whatman is a registered trademark of Cytiva
Palavra indicadora
Warning
Frases de perigo
Declarações de precaução
Código de classe de armazenamento
11 - Combustible Solids
Escolha uma das versões mais recentes:
Certificados de análise (COA)
Lamentamos, não temos COA para este produto disponíveis online no momento.
Se precisar de ajuda, entre em contato Atendimento ao cliente
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Os clientes também visualizaram
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica