372455
Graphite, fluorinated, polymer
extent of labeling: >61 wt. % F
Faça loginpara ver os preços organizacionais e de contrato
About This Item
Fórmula linear:
(CFx)n, x~1.1
Número CAS:
Número CE:
Número MDL:
Código UNSPSC:
12162002
NACRES:
NA.23
Produtos recomendados
Formulário
powder
Nível de qualidade
Extensão da rotulagem
>61 wt. % F
InChI
1S/C.F
chave InChI
PRPAGESBURMWTI-UHFFFAOYSA-N
Procurando produtos similares? Visita Guia de comparação de produtos
Aplicação
Used in cathodic materials, lubricants, image recording, pressure-sensitive copying and carbon filament incandescent lamps.
Palavra indicadora
Warning
Frases de perigo
Declarações de precaução
Classificações de perigo
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
Órgãos-alvo
Respiratory system
Código de classe de armazenamento
11 - Combustible Solids
Classe de risco de água (WGK)
WGK 3
Ponto de fulgor (°F)
Not applicable
Ponto de fulgor (°C)
Not applicable
Escolha uma das versões mais recentes:
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Vasilii I Artyukhov et al.
The journal of physical chemistry. A, 114(16), 5389-5396 (2010-04-08)
Carbon monofluoride (CF)(n) and graphane are two very different materials from the practical point of view, but the basic chemical motifs of these materials are closely related: both can be described as two-dimensional polycyclic (fluoro-/hydro-)carbons. However, the actual experimental data
W Greatbatch et al.
Pacing and clinical electrophysiology : PACE, 19(11 Pt 2), 1836-1840 (1996-11-01)
The reduction in pacemaker size coupled with the addition of more current demanding functions has motivated the development of batteries that can supply higher current densities at useful voltages than the lithium/iodine batteries in use today while retaining the volumetric
Thomas K Weldeghiorghis et al.
Journal of magnetic resonance (San Diego, Calif. : 1997), 165(2), 230-236 (2003-12-04)
Rotational-echo double resonance (REDOR) is a magic-angle spinning technique for measuring heteronuclear dipolar couplings. Rotor-synchronized pi pulses recouple the dipolar interaction. The accuracy of a REDOR determination of distance or orientation depends totally on the quality of the dephased (recoupled)
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica