Pular para o conteúdo
Merck
Todas as fotos(3)

Key Documents

203645

Sigma-Aldrich

Lithium fluoride

greener alternative

powder, <100 μm, ≥99.98% trace metals basis

Sinônimo(s):

Fluorolithium

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Fórmula linear:
LiF
Número CAS:
Peso molecular:
25.94
Número CE:
Número MDL:
Código UNSPSC:
12352302
ID de substância PubChem:
NACRES:
NA.23

Ensaio

≥99.98% trace metals basis

forma

powder

características do produto alternativo mais ecológico

Design for Energy Efficiency
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

Impurezas

≤200.0 ppm Trace Metal Analysis

tamanho de partícula

<100 μm

pb

1673 °C/1 atm (lit.)

pf

845 °C (lit.)

solubilidade

aqueous acid: slightly soluble(lit.)

densidade

2.64 g/mL at 25 °C (lit.)

categoria alternativa mais ecológica

cadeia de caracteres SMILES

[Li+].[F-]

InChI

1S/FH.Li/h1H;/q;+1/p-1

chave InChI

PQXKHYXIUOZZFA-UHFFFAOYSA-M

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

We are committed to bringing you Greener Alternative Products, which adhere to one or more of The 12 Principles of Greener Chemistry. This product has been enhanced for energy efficiency. Click here for more information.

Aplicação

Lithium fluoride can be used as an electron injection layer in the fabrication of electroluminescent devices.

It can be used as an electrolyte additive to protect the lithium metal electrode, which improves the stability and reversibility of the battery. The partially soluble LiF forms a thin coating over the surface of lithium and stabilizes the SEI layer.

It can also be used as catalyst support in the preparation of carbon nanofibers by a catalytic chemical vapor deposition method.

Características e benefícios

  • High mechanical strength
  • Wide electrochemical stability window
  • Low calculated barriers toLi diffusion

Pictogramas

Exclamation mark

Palavra indicadora

Warning

Frases de perigo

Classificações de perigo

Acute Tox. 4 Oral - Eye Irrit. 2

Perigos de suplementos

Código de classe de armazenamento

13 - Non Combustible Solids

Classe de risco de água (WGK)

WGK 2

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable

Equipamento de proteção individual

Eyeshields, Faceshields, Gloves, type P2 (EN 143) respirator cartridges


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

Hatem Dachraoui et al.
Optics express, 19(3), 2797-2804 (2011-03-04)
We report a femtosecond crystallographic study of the dependence of the free-carries generation to the alignment of a crystalline sample to the laser polarization. The probe pulse transmission exhibits a π/2 modulation that is shown to be correlated with the
R Takam et al.
Radiation protection dosimetry, 150(1), 22-33 (2011-08-30)
(6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescent dosemeters (TLDs) were used for measurements of out-of-field photon and neutron doses produced by Varian iX linear accelerator. Both TLDs were calibrated using 18-MV X-ray beam to investigate their dose-response sensitivity and linearity. CR-39 etch-track
Thorsten Grünheid et al.
American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 141(4), 436-443 (2012-04-03)
Cone-beam computed tomography (CBCT) has become a routine imaging modality for many orthodontic clinics. However, questions remain about the amount of radiation patients are exposed to during the scans. This study determined the amounts of radiation potentially absorbed by a
Christian Bernhardsson et al.
Health physics, 103(6), 740-749 (2012-11-01)
Laboratory studies have shown that ordinary household salt (NaCl) exhibits several promising properties for retrospective dosimetry; e.g., a linear dose response and a low detection limit, down to a few mGy or even less. In an attempt to test NaCl
Igor Rahinov et al.
Physical chemistry chemical physics : PCCP, 13(28), 12680-12692 (2011-06-17)
The Born-Oppenheimer Approximation (BOA) forms the basis for calculating electronically adiabatic potential energy surfaces, thus providing the framework for developing a molecular level understanding of a variety of important chemical problems. For surface chemistry at metal surfaces, it is now

Artigos

Professor Gogotsi and Dr. Shuck introduce MXenes: a promising family of two-dimensional materials with a unique combination of high conductivity, hydrophilicity, and extensive tunability.

Research and development of solid-state lithium fast-ion conductors is crucial because they can be potentially used as solid electrolytes in all-solid-state batteries, which may solve the safety and energy-density related issues of conventional lithium-ion batteries that use liquid (farmable organic) electrolytes.

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica