跳轉至內容
Merck
全部照片(1)

重要文件

56197

Supelco

3-羟基-2-吡啶甲酸

matrix substance for MALDI-MS, ≥99.0% (HPLC)

同義詞:

3-HPA, 3-羟基吡啶-2-羧酸

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C6H5NO3
CAS號碼:
分子量::
139.11
Beilstein:
118954
EC號碼:
MDL號碼:
分類程式碼代碼:
12000000
PubChem物質ID:
NACRES:
NA.21

等級

matrix substance for MALDI-MS

品質等級

化驗

≥99.0% (HPLC)

形狀

powder or crystals

分析物化學類別

oligonucleotides, oligosaccharides

技術

MALDI-MS: suitable

mp

213-218 °C (lit.)

正離子痕跡

Ba: ≤5 mg/kg
Ca: ≤50 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤20 mg/kg
K: ≤20 mg/kg
Mg: ≤50 mg/kg
Mn: ≤5 mg/kg
Na: ≤100 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Zn: ≤50 mg/kg

SMILES 字串

OC(=O)c1ncccc1O

InChI

1S/C6H5NO3/c8-4-2-1-3-7-5(4)6(9)10/h1-3,8H,(H,9,10)

InChI 密鑰

BRARRAHGNDUELT-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

應用

3-羟基吡啶甲酸(3-HPA)是一种基质材料,用于通过基于基质辅助激光解吸/电离(MALDI)的质谱法分析生物大分子和定量寡核苷酸。

包裝

无底玻璃瓶。内容物在嵌入的融合锥中。

其他說明

3-羟基吡啶甲酸用于研究表层沉积物中喹啉降解细菌的分离和表征。

相關產品

產品號碼
描述
訂價

象形圖

Exclamation mark

訊號詞

Warning

危險聲明

危險分類

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

標靶器官

Respiratory system

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

dust mask type N95 (US), Eyeshields, Gloves


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Isolation and characterization of quinoline-degrading bacteria from subsurface sediments.
Applied and Environmental Microbiology, 55 (4), 1029-1032 (1989)
K Tang et al.
Nucleic acids research, 23(16), 3126-3131 (1995-08-25)
Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry was used to analyze short DNA duplex probes with one strand immobilized on solid supports (straptavidin-coated magnetic beads or controlled pore glass beads). Only the non-immobilized strand could be detected. Partial denaturation
P Juhasz et al.
Carbohydrate research, 270(2), 131-147 (1995-04-30)
Molecular weights of heparin-derived oligosaccharides ranging from disaccharides to hexadecasaccharides have been determined by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. While these compounds ionize poorly or not at all when used as such, a strong signal can be obtained
Gas-phase diagnostics and LIF-imaging of 3-hydroxypicolinic acid MALDI-matrix plumes
Puretzky AA and Geohegan DB
Chemical Physics Letters, 286(5-6), 425-432 (1998)
H Suzuki et al.
Analytical chemistry, 69(22), 4554-4559 (1998-01-07)
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), has been used for structure characterization of 1-aminopyrene-3,6,8-trisulfonate (APTS)-derivatized oligosaccharides previously separated by capillary electrophoresis (CE). The resolved components were first isolated by employing an automated high-resolution fraction collector. Using on-probe sample

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務