Przejdź do zawartości
Merck
Wszystkie zdjęcia(3)

Kluczowe dokumenty

M1882

Sigma-Aldrich

Myoglobin from equine heart

≥90% (SDS-PAGE), essentially salt-free, lyophilized powder

Synonim(y):

Myoglobin from horse heart

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Numer CAS:
Numer WE:
Numer MDL:
Kod UNSPSC:
12352202
NACRES:
NA.61

pochodzenie biologiczne

equine heart

Poziom jakości

Próba

≥90% (SDS-PAGE)

Formularz

essentially salt-free, lyophilized powder

Zawartość żelaza

≥0.20%

metody

MALDI-MS: suitable

numer dostępu UniProt

temp. przechowywania

−20°C

informacje o genach

horse ... MB(100054434)

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Zastosowanie

Myoglobin from equine heart is suitable for use in:
  • spectral measurements in Beckman DU-50 or Gilford 2400 spectrophotometer
  • the secondary structure analysis of proteins in H2O solution using single-pass attenuated total reflection Fourier transform infrared (ATR-FT-IR) microscopy
  • the calibration of the mass scale at a concentration of 2 pmol/μL in Electrospray mass spectrometry
  • a study to investigate on-line single droplet deposition for MALDI mass spectrometry
  • a study to examine protein adsorption in fused-silica and polyacrylamide-coated capillaries

Działania biochem./fizjol.

Myoglobin is a mobile carrier of oxygen that is developed in red muscle and heart cells. This happens as a response to elevated demand for oxygen during exercise, and transports oxygen from the sarcolemma to the mitochondria of vertebrate heart and red muscle cells.
Ta strona może zawierać tekst przetłumaczony maszynowo.

Kod klasy składowania

11 - Combustible Solids

Klasa zagrożenia wodnego (WGK)

WGK 3

Temperatura zapłonu (°F)

Not applicable

Temperatura zapłonu (°C)

Not applicable

Środki ochrony indywidualnej

Eyeshields, Gloves, type N95 (US)


Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Ursula Waack et al.
mBio, 9(6) (2018-12-20)
Antibiotic-resistant Acinetobacter baumannii is increasingly recognized as a cause of difficult-to-treat nosocomial infections, including pneumonia, wound infections, and bacteremia. Previous studies have demonstrated that the metalloprotease CpaA contributes to virulence and prolongs clotting time when added to human plasma as
D H Robertson et al.
Rapid communications in mass spectrometry : RCM, 11(7), 786-790 (1997-01-01)
Major urinary proteins (MUPs) from the urine of individual wild mice were characterized using electrospray ionization mass spectrometry (ESI-MS) and compared to MUPs from the urine of inbred mice. The wild mice showed considerable variation between individuals in the expression
Guadalupe Gómez-Baena et al.
Scientific reports, 9(1), 10757-10757 (2019-07-26)
Major urinary proteins (MUP) are the major component of the urinary protein fraction in house mice (Mus spp.) and rats (Rattus spp.). The structure, polymorphism and functions of these lipocalins have been well described in the western European house mouse
Cassandra M Stawicki et al.
Scientific reports, 11(1), 19921-19921 (2021-10-09)
Fluorescently labeled antibody and aptamer probes are used in biological studies to characterize binding interactions, measure concentrations of analytes, and sort cells. Fluorescent nanoparticle labels offer an excellent alternative to standard fluorescent labeling strategies due to their enhanced brightness, stability
V Kery et al.
The Journal of biological chemistry, 269(41), 25283-25288 (1994-10-14)
The first committed step of transsulfuration is catalyzed by cystathionine beta-synthase (CBS), a known pyridoxal 5'-phosphate (PLP) enzyme. The inferred amino acid sequences of rat liver CBS and rat liver hemoprotein H-450 are identical. We now confirm the presence of

Produkty

Zestaw do szybkiego trawienia trypsyną zapewnia wiarygodne wyniki analizy spektrometrii masowej w czasie krótszym niż 2 godziny.

In this study, we developed a rapid trypsin digest kit that, at elevated temperatures, yielded reliable, reproducible results in less than 2 hours on a wide variety of substrates for mass spectrometry.

Protokoły

Separation of HPLC protein standard mixture, analytical standard

Chromatograms

application for HPLC

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej