Przejdź do zawartości
Merck

70425

Sigma-Aldrich

Atto 590

BioReagent, suitable for fluorescence, ≥90% (HPLC)

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Wzór empiryczny (zapis Hilla):
C37H39ClN2O9
Masa cząsteczkowa:
691.17
Numer MDL:
Kod UNSPSC:
12352108
NACRES:
NA.32

linia produktu

BioReagent

Poziom jakości

Próba

≥90% (HPLC)

Formularz

powder

producent / nazwa handlowa

ATTO-TEC GmbH

λ

in ethanol (with 0.1% trifluoroacetic acid)

absorpcja UV

λ: 595-601 nm Amax

przydatność

suitable for fluorescence

temp. przechowywania

−20°C

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Zastosowanie

Atto fluorescent labels are designed for high sensitivity applications, including single-molecule detection. Atto labels have rigid structures that do not show any cis-trans isomerization. Thus these labels display exceptional intensity with minimal spectral shift on conjugation.
Atto 590 shows a molar extinction of 120,000 and QY of 80% in water (90% in ethanol). Decay time is 3.7 ns.
Employed in fluorescence energy transfer, FRET, microscopy.

Informacje prawne

This product is for Research use only. In case of intended commercialization, please contact the IP-holder (ATTO-TEC GmbH, Germany) for licensing.
Ta strona może zawierać tekst przetłumaczony maszynowo.

Kod klasy składowania

11 - Combustible Solids

Klasa zagrożenia wodnego (WGK)

WGK 3

Temperatura zapłonu (°F)

Not applicable

Temperatura zapłonu (°C)

Not applicable

Środki ochrony indywidualnej

Eyeshields, Gloves, type N95 (US)


Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Nie widzisz odpowiedniej wersji?

Jeśli potrzebujesz konkretnej wersji, możesz wyszukać konkretny certyfikat według numeru partii lub serii.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Klienci oglądali również te produkty

Slide 1 of 2

1 of 2

Matthew Antonik et al.
The journal of physical chemistry. B, 110(13), 6970-6978 (2006-03-31)
We establish a probability distribution analysis (PDA) method for the analysis of fluorescence resonance energy transfer (FRET) signals to determine with high precision the originating value of a shot-noise-limited signal distribution. PDA theoretical distributions are calculated explicitly including crosstalk, stochastic
D Wildanger et al.
Journal of microscopy, 236(1), 35-43 (2009-09-24)
The advent of supercontinuum laser sources has enabled the implementation of compact and tunable stimulated emission depletion fluorescence microscopes for imaging far below the diffraction barrier. Here we report on an enhanced version of this approach displaying an all-physics based
Uffe V Schneider et al.
Nucleic acids research, 38(13), 4394-4403 (2010-03-27)
Twisted intercalating nucleic acid (TINA) is a novel intercalator and stabilizer of Hoogsteen type parallel triplex formations (PT). Specific design rules for position of TINA in triplex forming oligonucleotides (TFOs) have not previously been presented. We describe a complete collection
Subunit rotation in a single F0F1-ATP synthase in a living bacterium monitored by FRET.
Seyfert, K.,et al.
Proceedings of SPIE, 7905, 79050K-79050K (2011)
SNARE Function Is Not Involved in Early Endosome Docking.
Geumann, U.; et al.
Molecular Biology of the Cell, 19(12), 5327-5337 (2008)

Produkty

Pomiar czasu życia fluorescencji ma przewagę nad pomiarami opartymi na intensywności. Zastosowania obejmują testy czasu życia fluorescencji, wykrywanie i FLI.

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej