LAGB04TP6
Durapore® 0.22 µm, Optiseal® Cartridge
pore size 0.22 μm, OptiSeal® 4 in., filtration area 0.18 m2, matrix Durapore®
Synonim(y):
Optiseal® Durapore® Cartridge Filter 0.22 µm hydrophobic
About This Item
Polecane produkty
Materiały
PVDF
polypropylene
polypropylene support
silicone seal
Poziom jakości
sterylność
non-sterile
Kompatybilność ze sterylizacją
steam-in-place compatible
steam-in-place compatible
linia produktu
OptiSeal® 4 in.
Właściwości
hydrophobic
producent / nazwa handlowa
OptiSeal®
Parametry
≤2 mL/min nitrogen diffusion at 1.0 bar (15 psig) and 23 °C (in 60/40% IPA/water)
0.35 bar max. differential pressure (5 psid) at 121 °C (Forward)
0.35 bar max. inlet pressure (5 psi) at 135 °C (Forward)
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse)
3.5 bar max. differential pressure (50 psid) at 80 °C (Forward)
3.5 bar max. inlet pressure (50 psi) at 25 °C (Reverse)
3.5 bar max. inlet pressure (50 psi) at 80 °C (Forward)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)
metody
sterile filtration: suitable
Długość
4 in.
długość nominalna kartridża
4 in. (10 cm)
powierzchnia filtracyjna
0.18 m2
zanieczyszczenia
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
substancje ekstrahujące się grawimetrycznie
≤10 mg/cartridge
macierz
Durapore®
wielkość porów
0.22 μm pore size
moc wejściowa
sample type liquid
punkt pęcherzykowania
≥1240 mbar (18 psig), nitrogen with 60/40% IPA/water at 23 °C
kod wkładu
not applicable
Opis ogólny
Opakowanie
Inne uwagi
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Uwaga dotycząca przygotowania
30 SIP cycles of 30 min @ 135 °C; 10 autoclave cycles of 30 min @ 126 °C
Komentarz do analizy
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Informacje prawne
Nie możesz znaleźć właściwego produktu?
Wypróbuj nasz Narzędzie selektora produktów.
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej