Przejdź do zawartości
Merck
Wszystkie zdjęcia(1)

Kluczowe dokumenty

KGSKG3TTT1

Millipore

Millipore Express® SHC, Opticap® XLT Capsule

Opticap® XLT 30, cartridge L 34.3 in. (87.2 cm), filter diam. 2.7 in. (6.9 cm)

Synonim(y):

Gamma Opticap® XLT HBP 30 Express SHC TC/TC

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
23151806

Materiały

polyethersulfone filter (PES)
polyethylene support
polypropylene housing (PP)
silicon seal

Poziom jakości

zgodność regionalna

meets FDA CFR 210.3 (b) (6) (all component materials)

sterylność

irradiated
non-sterile

Kompatybilność ze sterylizacją

gamma compatible

linia produktu

Opticap® XLT 30

Właściwości

hydrophilic

Parametry

1.0 bar max. inlet pressure (15 psi) at 80 °C
1000 mbar max. differential pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. inlet pressure (80 psi) at 25 °C
5500 mbar max. differential pressure (80 psi) at 25 °C
6.9 bar max. inlet pressure (100 psi) at 25 °C
76 L/min flow rate at 69 mbar (1 psi) and 23 °C
80 psig max. inlet pressure

metody

sterile filtration: suitable

Szerokość

7.8 in.

Wkład wys.

34.3 in. (87.2 cm)

Rozmiar urządzenia

30 in. (75 cm)

śr. filtra

2.7 in. (6.9 cm)

powierzchnia filtracyjna

1.62 m2

zanieczyszczenia

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)

Matryca

Millipore Express® SHC

pore size

0.5/0.2 μm pore size

punkt pęcherzykowania

≥4000 mbar (≥70 psig), air with water

dopasowywanie

1/4 in. fitting (vent/drain hose barb with double O-ring seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Opis ogólny

Cartidge Type: Liquid

Device Configuration: Capsule

Opakowanie

Double Easy-Open bag

Uwaga dotycząca przygotowania

Sterilization Note:
3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Komentarz do analizy

TOC/Conductivity: After sterilization and a controlled water flush of 63 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 μS/cm per USP <645> at 25 °C.

Inne uwagi

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer to wetting instructions of Filters with Millipore Express® Membrane use guide
  • Storage Statement: Please refer to Filters with Millipore Express® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Informacje prawne

MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.

Nie możesz znaleźć właściwego produktu?  

Wypróbuj nasz Narzędzie selektora produktów.


Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej