1.30194
HY-LiTE® Liquid Test Pens for Free ATP
Test pens for detection of Free ATP in liquid samples using HY-LiTE® 2/2A luminometers
Synonim(y):
Liquid ATP pens, Liquid ATP swabs, Liquid ATP tests, Liquid ATP samplers
Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych
About This Item
Polecane produkty
linia produktu
HY-LiTE®
producent / nazwa handlowa
HY-LiTE®
opakowanie
pkg of (Pkg of 50 pens)
Zastosowanie
cosmetics
food and beverages
water monitoring
kompatybilność
for use with HY-LITE® luminometer
metoda wykrywania
bioluminescent
temp. przechowywania
2-8°C
Powiązane kategorie
Opis ogólny
The HY-LiTE® Liquid Test Pens for Free ATP are ready prepared Pens to measure the Free ATP (Adenosine triphosphate) in liquid samples using the HY-LiTE® 2/2A luminometer. ATP is detected by reaction with a luciferin/luciferase reagent in buffered solution.
Compared to the HY-LiTE® Liquid Test Pen for Total ATP (1.30102), the white sampling stick of the Liquid Pen for Free ATP does not contain a lysis reagent. Therefore, bacterial cells are not lysed and only the free ATP in the liquid solution is measured. A comparative measurement using both HY-LiTE® liquid pens (1.30102 Total ATP and 1.30194 Free ATP) can be performed in order to provide information on the proportion of cellularly bound ATP.
Compared to the HY-LiTE® Liquid Test Pen for Total ATP (1.30102), the white sampling stick of the Liquid Pen for Free ATP does not contain a lysis reagent. Therefore, bacterial cells are not lysed and only the free ATP in the liquid solution is measured. A comparative measurement using both HY-LiTE® liquid pens (1.30102 Total ATP and 1.30194 Free ATP) can be performed in order to provide information on the proportion of cellularly bound ATP.
Zastosowanie
HY-LiTE® Liquid Test Pens for Free ATP are used for monitoring CIP (Cleaning in Place) rinse waters, biomass monitoring in biocide water treatment, or other liquid samples by measuring with the HY-LiTE® 2/2A luminometer.
Przydatność
For detection of Free ATP in liquid samples to monitor biomass
Powiązanie
Replaces: 1.30194.0022
Komentarz do analizy
packaging: conforms
Appearance: Red caps
Performance test: conforms
Appearance: Red caps
Performance test: conforms
Informacje prawne
HY-LITE is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.
Kod klasy składowania
12 - Non Combustible Liquids
Klasa zagrożenia wodnego (WGK)
WGK 2
Temperatura zapłonu (°F)
Not applicable
Temperatura zapłonu (°C)
Not applicable
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.