Key Documents

I-026

Supelco

Interference Mix 4 (For Qualitative Use Only)

5-100 μg/mL each component in methanol, Cerilliant®

동의어(들):

Qualitative Interference Mixture

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41116107
NACRES:
NA.24

Grade

analytical standard

형태

liquid

구성

Alprazolam, 100 μg/mL
Cimetidine, 100 μg/mL
Citalopram hydrobromide, 100 μg/mL (as free base)
Clonazepam, 100 μg/mL
Clopidogrel bisulfate, 100 μg/mL (as free base)
Dextromethorphan, 50 μg/mL
Fluconazole, 100 μg/mL
Hydrochlorothiazide, 100 μg/mL
Lamotrigine, 100 μg/mL
Methylphenidate hydrochloride, 100 μg/mL (as free base)
Omeprazole, 100 μg/mL
L-Thyroxine, 5 μg/mL

포장

ampule of 1 mL

제조업체/상표

Cerilliant®

drug control

psicótropo (Spain); Decreto Lei 15/93: Tabela IV/IIB (Portugal)

농도

5-100 μg/mL each component in methanol

기술

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

응용 분야

forensics and toxicology

형식

single component solution

저장 온도

−20°C

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

A multi-component solution standard of routinely monitored over-the-counter (OTC) and prescription drugs alprazolam; cimetidine; citalopram HBr; clonazepam; clopidogrel bisulfate; dextromethorphan; fluconazole; hydrochlorothiazide; lamotrigine; L-thyroxine; methylphenidate HCl; and omeprazole. This standard is for qualitative use only in the evaluation of interferences between the mix components and target analytes of interest in a testing laboratory′s analytical methods.

애플리케이션


  • VOCs Determination in Complex Mixtures: Metal oxide-based gas sensor arrays enhanced with machine learning, utilizing Interference Mix 4 for calibration and validation, revolutionize volatile organic compounds analysis in biotechnological applications (Singh et al., 2024).

  • Ammonia Sensing Technology: Development of a highly sensitive ammonia sensor using a PMMA/PANI microwire structure, where Interference Mix 4 serves to test interference resilience, pivotal for maintaining lab environment quality in pharma research (Cheng et al., 2024).

  • Anticoagulant Interference in Medical Testing: Simplified method for removing direct oral anticoagulant interference in mechanical coagulation test systems, employing Interference Mix 4 to validate the approach, essential for accurate clinical diagnostics in medical biotechnology (Exner et al., 2024).

법적 정보

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany

픽토그램

FlameSkull and crossbonesHealth hazard

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

표적 기관

Eyes,Central nervous system

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point (°F)

49.5 °F - closed cup

Flash Point (°C)

9.7 °C - closed cup