コンテンツへスキップ
Merck

LNEBIO101L1

Glucose, Creatinine, Glycerides, Cholesterol, in human frozen serum

LNE Certified Reference Material, commutable, JCTLM listed

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
12352211
NACRES:
NA.24

形状

liquid

品質

commutable, JCTLM listed

シェルフライフ

limited shelf life, expiry date on the label

組成

human serum, 100%

体外診断薬

not for in vitro diagnostic use

保管温度

−70°C

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

LNE CRM Bio 101L1 is a JCTLM database listed, higher-order certified reference material produced by the French metrological institute LNE in compliance with ISO 17034 requirements.
The Certified Reference Materials LNE CRM Bio 101L1 and LNE CRM Bio 101L2 correspond to 2 pools of Human Frozen Serum that were prepared according to the Clinical Laboratory Standards Institute (CLSI) C37-A guidelines describing the preparation and validation of commutable frozen human serum pools as Secondary Reference Materials for Cholesterol Measurement. Samples commutability was assessed through 2 commutability studies according to the difference in bias approach described in the IFCC recommendations on commutability assessment involving several clinical laboratories. Commutability results are reported in the certificate of analysis.

Cert_ LNE CRM Bio 101L1

アプリケーション

LNE CRM Bio 101L1, a secondary standard, is intended for use as quality control material to assess the measurement bias or measurement uncertainty of established or new measurement procedures for the determination of creatinine, glucose, total cholesterol, total glycerides, HDL-cholesterol and LDL-cholesterol in human serum.

特徴および利点

  • A reliable Certified Reference Material (CRM) for clinically relevant biomarkers 
  • Concentrations of glucose, creatinine, total cholesterol, triglyceride (TG), high-density lipoprotein (HDL)-cholesterol and low-density lipoprotein (LDL)-cholesterol are certified by higher-order reference methods. 
  • Derived from real patient samples 
  • This CRM is pooled, tested, and certified by the LNE, which includes extensive commutability studies. 
  • The accuracy of the reference methods used to certify target values is verified using certified matrix reference materials. 
  • Listed by the JCTLM as higher-order reference materials.

その他情報

  • Details on storage, safety, usage, and operating instructions are provided in the comprehensive Certificate of Analysis (CoA). 
  • Concentrations of glucose, creatinine, total glycerides and total cholesterol are certified by reference measurement procedures relying on Gas Chromatography Isotope Dilution mass Spectrometry (GC-IDMS) listed in JCTLM  database. 
  • Concentrations of HDL-C and LDL-C are certified at the CDC by Beta Quantification with cholesterol being determined by the Abell Kendall method. 
  • This clinical matrix CRM is for research and clinical testing applications. 

保管分類コード

12 - Non Combustible Liquids

WGK

WGK 1

引火点(°F)

Not applicable

引火点(℃)

Not applicable


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

LNEBIO101L1-1EA:


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)