コンテンツへスキップ
Merck

LNEBIO302

Glucose, Creatinine, Glycerides, Cholesterol, Urea and Uric acid in human frozen serum

LNE Certified Reference Material

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
12352211
NACRES:
NA.24

フォーム

liquid

シェルフライフ

limited shelf life, expiry date on the label

組成

human serum, 100%

体外診断薬

not for in vitro diagnostic use

保管温度

−70°C

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

LNE CRM Bio 302 is a higher-order certified reference material produced by the French metrological institute LNE in compliance with ISO 17034 requirements. This secondary standard is intended for use as quality control material to assess the measurement bias or measurement uncertainty of established or new measurement procedures for the determination of creatinine, glucose, total cholesterol, total glycerides, HDL-cholesterol and LDL-cholesterol in human serum.
The Certified Reference Material LNE CRM Bio 302 corresponds to a pool of Human Frozen Serum that was prepared according to the Clinical Laboratory Standards Institute (CLSI) C37-A guidelines describing the preparation and validation of commutable frozen human serum pools as Secondary Reference Materials for Cholesterol Measurement. Samples commutability was assessed through a commutability study involving several clinical laboratories. Commutability results are reported in the certificate of analysis.

Cert_ LNE CRM Bio 302

アプリケーション

LNE CRM Bio 302, a secondary standard, is intended for use as quality control material to assess the measurement bias or measurement uncertainty of established or new measurement procedures for the determination of creatinine, glucose, total cholesterol, total glycerides, HDL-cholesterol and LDL-cholesterol in human serum.

特徴および利点

  • A reliable certified reference materials (CRM) for clinically relevant biomarkers 
  • Concentrations of glucose, creatinine, total cholesterol, triglyceride (TG), high-density lipoprotein (HDL)-cholesterol, low-density lipoprotein (LDL)-cholesterol, urea, and uric acid, are certified with higher-order reference methods. 
  • Derived from real patient samples. 
  • This CRM is pooled, tested, and certified by the LNE, which includes extensive commutability studies. 
  • Commutability assessed for the main routine assays.
  • The accuracy of the reference methods used to certify target values is verified using certified matrix reference materials. 
  • This CRM was used for national quality control organized by the ANSM in 2016 to assess the accuracy of some general biochemistry tests. 

その他情報

  • Details on storage, safety, usage, and operating instructions are provided in the comprehensive Certificate of Analysis. 
  • Concentrations of glucose, total glycerides, and total cholesterol are certified by reference measurement procedures relying on gas chromatography isotope dilution mass spectrometry (GC-IDMS) listed in JCTLM database.  
  • Concentrations of HDLC and LDL-C, are certified at the CDC by beta quantification with cholesterol being determined by the Abell Kendall method. 
  • Concentrations of creatinine and uric acid are certified by reference measurement procedures relying on liquid chromatography isotope dilution mass spectrometry (LC-IDMS) listed in JCTLM database. 
  • This clinical matrix CRM is for research and clinical testing applications. 

保管分類コード

10 - Combustible liquids

WGK

WGK 1

引火点(°F)

Not applicable

引火点(℃)

Not applicable


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

LNEBIO302-1EA:


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)